Operating
Manual
Symptom
Items to check
Suggested fix
Difficulty inserting clamp
tail into tool.
Is there a clamp tail already in the
tool?
Remove previous clamp tail.
Do the gauges on the control module
show pressure?
Check incoming supply pressure.
Turn the air regulator valve ON.
Tool does not cycle
when the trigger is
pressed.
Do the gauges on the control module
show pressure?
Check incoming supply pressure.
Turn the air regulator valve ON.
Check for pinched air lines under the
handle cover.
Tool tightens clamp, but
cutoff does not activate.
After the tool stalls, does nothing
further happen? (no sound of the
cylinder moving)
Check for pinched air lines.
Check cutoff timing.
Does the cylinder sound as though it
moves, but the knife does not extend?
Remove the side body and verify all links
are present and connected.
Verify there is a knife installed.
Tool attempts to cutoff
and lock the clamp
before it is tight.
Is the cutoff timing too short?
Adjust cutoff timing.
Is the tool struggling to pull up the
clamp?
Increase tension pressure.
Lubricate the tool.
Tool fails to cut or lock
clamp.
(Press reset button to
release tool from clamp if
stalled)
Check tension and cutoff pressures.
Adjust pressure regulators if not set at
specification. Verify that the hose from the
tension regulator enters the bottom port of
the tool.
Check knife and blade for excessive
wear or chips on the cutting edges.
Replace as necessary.
Clamp is loose after
cutoff.
For TLT/ IT1000, Check dimple punch
& tool orientation allowing buckle to
enter dimple clip.
For JR/ IT2000,check that proper
blade is installed .
Replace damaged or incorrect parts;
assemble with buckle entering dimple clip.
Do not allow fixture interference with tool
motion.
Contact BAND-IT-IDEX Customer Service at 1-800-525-0758 or 303-320-4555 for
repair on any issues not addressed above.
Trouble Shooting Guide: Tool Symptoms