5. Troubleshooting
5. Troubleshooting
1. No Fluid Flow
1) Check to see if SHAFT is in proper operation.
2) Make sure that fluid is not hardened.
3) Check to see if fluid needs to be refilled.
4) Be sure that the controller as well as other appliances are properly powered.
5) Check the air supply.
6) Make sure no shift is made in air line.
2. Fluid Leakage
1) If fluid leaks from the nozzle, remove the needle adapter No. 14 and clean up dirt in Seat Cap(Ni,4-1)
or replace the Valve Seat 17.
2) If fluid leakage occurs in the Packing Pusher Hole No 5, replace the Teflon Packing in it.
3) If leakage is due to the Shaft worn-out, replace No.9.
2. Cleaning
2. Cleaning
2. Cleaning
2. Cleaning
1) How to Clean
① Stop providing liquid and disassemble.
② Connect the cleaning line to fluid supply line and add pressure.
③ Follow the operation guide of 3-2 and dispense cleaning liquid instead of fluid.
2) Caution
To minimize possible damage on skin or eyes by fluid, please strictly follow the procedure for
air-release before part-replacement or valve-cleaning.
3) How to Release Air Pressure
① Cut off the supply of air and fluid into the dispensing valve.
② With the valve facing In a round container, open the valve and dispense liquid to remove
the pressure.