Assembling procedure
1) Prepare a cement platform perfectly straight and level to fix the
body. On the center of this platform place the plastic pipes for the
electrical wiring and the fixing plate .
3) Fix the body on the fixing plate.
4) Install the arm in the arm support (see pag. 9/10).
5) Unlock the motoreducer (pag. 5) and set the spring using the
regulation screw placed below the spring. Check that
the arm
movement is smooth and uniform. (see pag. 11 )
.
6) Lock the motoreducer (pag 5), and proceed with the electrical
wiring (see attached manual).
7) Verify that the arm stops in horizontal position (closing)
and vertical position (opening).
If this position is to be adjusted, check the limitswitch magnets
and the rubber vibration dumpers
.
(see pag.11)
217
1
3
0
Hole diameter 15 mm
Screws diameter 12 mm
Are advise to be used
Ø
0
5
FIG.2
3
Barrier
RX
Photocell
AREA TO BE PROTECTED WITH SAFETY DEVICE
TX
Photocell
Fork
Arm
BEFORE PROCEEDING WITH INSTALLATION
MAKE SURE THAT THE OPERATING FIELD
OF THE BARRIER IS FREE FROM OBSTACLES
AND ELECTRIC CABLES.
TX
RX
RX
Magnetotermic
switch
Differential switch
CABINET FIXING
Cement
platform
Fixing screw
Plastic pipe
for electrical
Fixing plate
wiring
FIG. 1
230V
0V
ATTENTION:
BAME s.r.l. is liable only for the individual articles produced and sold by BAME. The gate with the
motor it’s considered a machine and must respect the machinery directives, the installer must verify
the safety of the gate with the motor and is liable for any damage due to a poor installation.
BAME is not liable for any damage depending on modifications to any particular: electrical, electronic
or mechanical done by other persons without prior consent by BAME s.r.l..
BAME is not liable for any damage depending on accessories, electronic control boards and
photocells without BAME trademark or for the use of these parts without prior consent by BAME s.r.l..
2) Use suitable screws to fix the plate on the platform.
DO NOT REGULATE
THE BARRIER WITH
THE MOTOR IN
FUNCTION!!
FIG.3