DESIGN CHARACTERISTICS
The burner consists of:
• Ventilating part in light aluminium alloy.
• Centrifugal fan for high performances.
• Intake air conveyor.
•
Combustion head complete with stainless steel nozzle.
• Flame inspection glass.
• Three-phase electric motor to run fan.
•
Air pressure switch to ensure the presence of combustion air.
•
Gas train complete with control valve, operating and safety valves,
valve seal control, minimum and maximum pressure switch, pressu
-
re control and gas filter.
•
Fuel flow rate regulation by means of servomotor controlling gas
valve and flow rate regulator.
•
Automatic burner command and control equipment with micropro
-
cessor in compliance with European standard EN298 integrated with
valve seal control.
•
Flame detection with sensor
•
Control panel including on/off and burner off switches, fuel selector,
operation and shut-down warning lights, keypad for programming
electronic cam.
•
Electrical system with protection rating IP54.
TECHNICAL FUNCTIONAL CHARACTERISTICS
•
Dual burner, able to operate alternately with natural gas or with die
-
sel (max viscosity 1.5° E at 20°C).
• EC approval according to European Standard EN 676 for natural
gas and Standard EN 267 for diesel.
•
Flame modulation operation for both fuels through electronic regula
-
tor, supplied on request.
•
Electronic command and control equipment with microprocessor.
•
Fuel / combustion air flow rate regulation by means of two servomo
-
tors controlled by the electronic equipment.
•
Combustion head with partial recirculation of combusted gases with
reduced emissions (class III according to EN 676 for natural gas,
class II according to EN 267 for diesel).
•
Hinge opens both ways to permit convenient access to the mixer
without dismantling the burner from the boiler.
•
Air minimum and maximum flow rate regulation by means of electric
stepper servomotor with pause closure of damper to prevent any
heat dispersion to flue.
•
Valve seal control and power regulation functions according to Eu
-
ropean Standard EN 676 (read carefully the operating instructions
given in the GUIDE supplied along with the burner for further details
about the equipment operations).
OPERATING RANGE
0
5
10
15
20
25
30
1
2
3
4
5
6
7
8
9
10
11
12
13 kW x 1000
Campo_lavoro_TBML1200ME
TBML 1200 ME
1
mbar / hPa
IMPORTANT
The working fields are obtained from test
boilers corresponding to the standard
EN267 for liquid fuels and EN676 for gas
fuels and are indicative for the combination
burner-boiler. For correct working of the
burner, the size of the combustion chamber
must correspond to current regulations; if
not the manufacturers must be consulted.
The burner shall not operate outside its spe
-
cific operating range.
1 Minimum power adjustable with diesel.
DANGER / ATTENTION
During the ignition and adjustment pha-
se, check that the maximum and minimum
outputs at which the burner is adjusted are
within the working range in order to avoid
damage to the system.
9 / 46
0006160318_202106
ENGLISH
Summary of Contents for TBML 1200 ME
Page 2: ......
Page 36: ...SCHEMI ELETTRICI TBML 1200ME 1600ME 2000ME BT 335 34 46 0006160318_202106 ITALIANO...
Page 37: ...TBML 1200ME 1600ME 2000ME BT 335 35 46 0006160318_202106 ITALIANO...
Page 38: ...TBML 1200ME 1600ME 2000ME BT 335 36 46 0006160318_202106 ITALIANO...
Page 39: ...TBML 1200ME 1600ME 2000ME BT 335 37 46 0006160318_202106 ITALIANO...
Page 40: ...BA I1 I2 I3 I4 TBML 1200ME 1600ME 2000ME BT 335 38 46 0006160318_202106 ITALIANO...
Page 42: ...SCHEMI ELETTRICI TBML 1200 1600 2000 ME 40 46 0006160318_202106 ITALIANO...
Page 43: ...TBML 1200 1600 2000 ME 41 46 0006160318_202106 ITALIANO...
Page 44: ...TBML 1200 1600 2000 ME 42 46 0006160318_202106 ITALIANO...
Page 45: ...TBML 1200 1600 2000 ME 43 46 0006160318_202106 ITALIANO...
Page 46: ...TBML 1200 1600 2000 ME I1 I2 I3 I4 BA 44 46 0006160318_202106 ITALIANO...
Page 48: ...46 46 0006160318_202106 ITALIANO...
Page 82: ...WIRING DIAGRAMS TBML 1200ME 1600ME 2000ME BT 335 34 46 0006160318_202106 ENGLISH...
Page 83: ...TBML 1200ME 1600ME 2000ME BT 335 35 46 0006160318_202106 ENGLISH...
Page 84: ...TBML 1200ME 1600ME 2000ME BT 335 36 46 0006160318_202106 ENGLISH...
Page 85: ...TBML 1200ME 1600ME 2000ME BT 335 37 46 0006160318_202106 ENGLISH...
Page 86: ...BA I1 I2 I3 I4 TBML 1200ME 1600ME 2000ME BT 335 38 46 0006160318_202106 ENGLISH...
Page 88: ...WIRING DIAGRAMS TBML 1200 1600 2000 ME 40 46 0006160318_202106 ENGLISH...
Page 89: ...TBML 1200 1600 2000 ME 41 46 0006160318_202106 ENGLISH...
Page 90: ...TBML 1200 1600 2000 ME 42 46 0006160318_202106 ENGLISH...
Page 91: ...TBML 1200 1600 2000 ME 43 46 0006160318_202106 ENGLISH...
Page 92: ...TBML 1200 1600 2000 ME I1 I2 I3 I4 BA 44 46 0006160318_202106 ENGLISH...
Page 94: ...46 46 0006160318_202106 ENGLISH...
Page 95: ......