46 / 96
0006081053_200801
E
N
G
L
I
S
H
DETAILS OF SUNTEC PUMP
8894-1
rev.05/04/96
AJ4 - AJ6
0002900331
rev. 05/04/96
AN 47 - 57 - 67 - 77 - 97
1 ELECTROVALVE (USUALLY CLOSED)
2 PRESSURE TEST POINT AND PUR
GE POINT (1/8” G)
3 PRESSURE REGULATION SCREW
3.1 REMOVE THE NUT TO HAVE ACCESS TO THE PRESSU
READJUSTMENT SCREW (AN..11-14 BAR, AJ..11-16 BAR)
4 RETURN
N.B. The pump is preset at a 12 bar pressure.
4.1 WAY-BACKWITH SCREW OF INNER BY-PASS
5 SUCTION
6 DELIVERY
7 VACUUM TEST POINT (1/8” G)
7.1 VACUUM GAUGE COUPLING