72
Balancing
BALTECH VP-3470
Operation manual
Figure 70. Trial run
Figure 71. Results of the trial run
9. Press Enter to start the measurement. The measurement process is completed
when the light indicator becomes green. Press Enter to move to CORR WEIGHTS
function (Figure 71). This window shows the recommended mass and installation
angle of the correction weight.
The correction weight is installed on the same radius of the balancing plane as
the trial weight. The installation angle of the correction weight is calculated from
the installation place of the trial weight towards or against direction of rotation
depending on the defined settings (Figure 63).
In this window you can also select the function VECTOR MATH and EXPECTED
VIBRATION by pressing the corresponding buttons. If the angle method is selected,