IX. SYSTEM TROUBLESHOOTING

Determining the causes of failures in an electrical system is a “step by step” process. We recommend that you inspect and clean all system
electrical connections before you begin your search to determine if the failure can be attributed to one of the two main components of your
charging system: the alternator, and/or the voltage regulator. 

Most charging system problems will be corrected by performing the following steps.

1.

Remove and clean all charging system electrical connections from the alternator through the batteries (this includes the ground side).

Also, check the voltage regulator’s harness for resistance. Wires and terminals can and will become corroded and need to be cleaned
or replaced.

2.

Charge all batteries to their proper fully charged state and determine if they are serviceable. If your batteries are flooded-type, use your

hydrometer to determine their condition.

3.

Check and tighten alternator belt. If the belt shows signs of wear or damage, now is an ideal time for replacement. Always replace

existing belts with the finest quality replacements available. 

After determining that your batteries and wiring are in suitable condition, use the following tests to determine if charging problems are a result
of a faulty alternator or regulator. The following tests provide an opportunity to isolate the alternator, regulator and wiring harness in order to
determine which component may be malfunctioning.  In order to preform these tests, you will need an independent multimeter (preferably a
digital type). In an emergency, a 24V light bulb can be used to help determine if power or working grounds exist. An amp meter and a bat-
tery hydrometer with a thermometer are also helpful diagnostic tools.

Alternator /Regulator  Field Tests

Test A -

The alternator and regulator can be tested for function by determining if a magnetic field exists at the alternator’s pulley shaft or rear

bearing. To test:

1.

With the ignition in the OFF position, place the head of a steel screwdriver near the nut on the pulley shaft or near the rear bearing of

the alternator. There should be no evidence of a magnetic field pulling the screwdriver toward the alternator.

2.

Engage the ignition, without starting the engine, to activate the voltage regulator. If an oil pressure switch is used, a jumper across the

switch will activate the regulator.

3.

After allowing time for the regulator’s start-up delay, place the head of a steel screwdriver near the nut on the pulley shaft or near the

rear bearing of the alternator. There should be evidence of a magnetic field pulling the screwdriver toward the alternator. If a magnet-
ic field is present, the voltage regulator, alternator brushes and rotor are likely to be working prop-
erly. If the system is not charging, remove the alternator and have it inspected by a qualified alter-
nator shop.

Test B - 

If there is little or no magnetic pull at the pulley shaft or at the rear bearing, initiate the follow-

ing test:

1.

With the key off and the engine off, remove the large harness plug from the regulator.

2.

Insert the end of a short length of electrical wire to the RED connector slot of the regulator har-

ness and the other end of the wire to the BLUE connector slot. (See 

Figure 18

.) This bypasses

the regulator and tests the alternator and the harness.

3.

Using your steel screwdriver, inspect for a magnetic field as described above.

4.

With your voltmeter, check for voltage on the blue wire at the alternator. If voltage does not exist,

the harness may be at fault. If voltage does exist at the harness, but charging is not occurring,
the alternator is likely to be malfunctioning.

If a magnetic field is present. Both harness and alternator brushes and rotor appear to be working prop-
erly. If no magnetic field is present, proceed with the next test. 

Test C -

Testing the actual output of the alternator is known as “Full Field Testing”. This can be accomplished by jumping a positive 24VDC

current to the field terminal at the rear of the alternator. This test eliminates both the regulator and the harness, making it easier to isolate
your investigation to the alternator. 

CAUTION: Ensure that all voltage sensitive equipment is turned off prior to starting the engine.

Voltage is unregulated during this test and could damage sensitive electronics. DO NOT let the engine run any longer than neces-
sary to detect charging.

To test the alternator:

1.

Clip a jumper wire to the positive post of the alternator, or on the battery side of the isolator, if an isolator is in use. Use a SHIELDED
alligator clip for post attachment. Unintentional contact between the  alligator clip and the alternator case could result in damage to
your electrical system.

2.

Disconnect the field/stator plug from the rear of the alternator and attach the other end of the jumper wire to the alternator’s Field ter-
minal (F). Attach a female spade connector to the field end of the wire for a solid connection. 

CAUTION:

Do not allow the wire to con-

tact the case while it is attached to the positive post. The case is grounded and severe damage could occur.

3.

The regulator is now bypassed. When the ignition is engaged and the motor is started, the voltage should rise and charging current
should be present. 

4.

The motor should be run long enough to determine that charging voltage is present. Unregulated voltage can rise quickly. Do not allow

extended unregulated charging to occur without carefully monitoring voltage levels.

If the alternator fails to generate voltage during field testing, a malfunction of the alternator is likely. Contact your local alternator repair shop
or Balmar’s technical service staff for recommendations. 

Voltage Regulator Test

When you have inspected and repaired any wires and connections, inspected belts and replace as needed, and after you have determined

- 7 -

R

Bl  

Figure 18 -

Jumping power wire

to field.

Summary of Contents for Max Charge MC-624

Page 1: ...hich could become entangled in your motor or other machinery 3 Wear ANSI approved safety glasses 4 DO NOT attempt to modify the regulator Alterations could result in damage to your charging system and...

Page 2: ...ts A tog gle switch may be added to this circuit to shut down the alternator load in cases where maximum propul sion is needed 5 The BLACK ground wire in the harness attaches to the System Ground Term...

Page 3: ...if needed Note An improperly installed or corroded battery terminal may generate heat and severe ly diminish charging and impede accurate temperature sensing 2 While observing polarity connect the ba...

Page 4: ...GEL For sealed gel batteries Absorbed Glass Mat AGL For AGM batteries Optima OPS For Optima spiral wound batteries Flooded Standard FSB For standard lead acid batteries Halogen HAL For voltage sensit...

Page 5: ...sensor reading in degrees Celcius LD Mode 10 Battery 2 temp Followed by the sensor reading in degrees Celcius LD Mode 11 Factory use only LD Mode 12 Factory use only LD Mode 13 Run time Hr code is fol...

Page 6: ...ACTIVATE RELEASE PrA Display cycles to Ec followed by OFF code 2 ACTIVATE HOLD OFF display cycles to numeric equalization time values When the manufacturer recommended time value is reached RELEASE E...

Page 7: ...qualified alter nator shop Test B If there is little or no magnetic pull at the pulley shaft or at the rear bearing initiate the follow ing test 1 With the key off and the engine off remove the large...

Page 8: ...and circuit damage or other system failures that could be responsible for charging dif ficulties If you determine that repair service is necessary for either your alternator or regulator please gather...

Reviews: