![Balmar DDC-12/24 Installation And Operation Manual Download Page 7](http://html1.mh-extra.com/html/balmar/ddc-12-24/ddc-12-24_installation-and-operation-manual_3589495007.webp)
7
www.balmar.net / Customer Service: +1 (360) 435-6100 x1 / Technical Support: +1 (360) 435-6100 x3
Tech Service is available Monday - Friday (8:30am - 7:30pm EST)
G G G G A A
1
3
4
5
G G G G A A
1
3
4
6
G G G G A A
1
3
4
G
G
G
G G G A A
1
3
5
6
G G G G A A
1
3
5
G G G G A A
1
3
6
G G G G A A
1
3
G G G G A A
1
6
G G G G A A
1
5
Lower & Upper Voltage Limits
12.3V 24.6V
12.4V 24.8V
12.5V 24.8V
12.6V 25.2V
12.7V 25.4V
12.8V 25.6V
12.9V 25.8V
13.0V 26.0V
13.1V 26.2V
G G G G A A
1
5
6
G G G G A A
1
4
G G G G A A
1
4
6
G G G G A A
1
4
5
G G G G A A
2
3
4
5
G G G G A A
2
3
4
6
G G G G A A
2
3
4
G G G G A A
2
3
5
6
G G G G A A
2
3
5
13.2V 26.4V
13.3V 26.6V
13.4V 26.8V
13.5V 27.0V
13.6V 27.2V
13.7V 27.4V
13.8V 27.6V
13.9V 27.8V
14.0V 28.0V
G G G G A A
2
3
6
G G G G A A
2
3
G G G G A A
2
6
G G G G A A
2
5
G G G G A A
2
5
6
G G G G A A
2
4
G G G G A A
2
4
6
G G G G A A
2
4
5
14.1V 28.2V
14.2V 28.4V
14.3V 28.6V
14.4V 28.8V
14.5V 29.0V
14.6V 29.2V
14.7V 29.4V
14.8V 29.6V
12V 24V
12V 24V
12V 24V
To program the upper voltage limit:
13. Re-activate the switch by returning the magnetic screwdriver to the RED dot when the #2 Amber LED is illuminated.
14. The 2# Amber LED will be joined by a number of sequenced Green LEDs as described in the chart below. Release
the magnet from the switch when the desired value is indicated.
15. The 2# Amber LED will re-illuminate, allowing you to change your programming choice, if needed.
16. If the reed switch is not re-activated, the display will cycle between the #1 and #2 Amber LEDs two more times. Both
#1 and #2 LEDs will flash together a total of eight times, indicating that your program choices have been saved.
Digital Duo Charge Terminal Legend
1. OUTPUT TERMINAL
2. MAGNETIC REED SWITCH
3. GROUND
4. BATTERY TEMP. (NEG.)
5. BATTERY TEMP. (POS.)
6. AUTO/MANUAL (NEG.)
7. ON/OFF (POS.)
8. SOLENOID DRIVE (NEG.)