background image

BALLY S6000 MONTE CARLO - QUICK SET-UP GUIDE 

 

1) 

If this is a new set up, begin with setting up the progressive Cham II board.  Make sure the 

Mikohn Cham II Eprom is installed on the board as often times it is removed by the casino for security 

reasons.  If this is a pre-running machine and you have allowed your rechargeable battery to die on your 

Cham II board then proceed to Step 2.  If your Cham II is functioning properly and showing your correct 

jackpot amount in the display window then proceed to Step 5 below. 

2) 

Make sure the display is hooked up and then power up the Mikohn box.  Set up the on-board 

options using the toggle switch and buttons with the display powered on.  Use the following settings: 

Menu = SYST 

 

Test = OFF 

 

Birth = OFF 

 

Save to = RAMD 

 

Show load = YES 

 

Show C1 = YES 

 

Symbol = NONE 

 

Sound = Disable 

 

Menu = ADDR 

 

GRADDR = 4 

 

ID ADDR = 64 

 

RTE ADDR = OFF 

 

MACH ADDR = 2 

 

 

 

 

Summary of Contents for MONTE CARLO S6000

Page 1: ...ery to die on your Cham II board then proceed to Step 2 If your Cham II is functioning properly and showing your correct jackpot amount in the display window then proceed to Step 5 below 2 Make sure the display is hooked up and then power up the Mikohn box Set up the on board options using the toggle switch and buttons with the display powered on Use the following settings Menu SYST Test OFF Birth...

Page 2: ...e cable contact us Once the program is started enter the Jackpot Programming section and enter the following parameters F3 SINGLE F4 M 08 F5 3 SEC F6 JP0 F7 F8 MS 00 Enter the desired base Jackpot base and current values Hidden Jackpot should be zero Jackpot limit should be 999 999 Increment 1 I suggest 12000 Increment 2 leave at zero After all the information is ready press F1 to send to the disp...

Page 3: ...ds in place Shorten the leads on your new battery and soldier to the existing leads Now study the board and insure the following settings are in place note this is assuming you are 25 cent denomination and you are using a WBA bill validator Contact us if you have something else DS1 1 ON 2 ON 3 ON 4 ON 5 OFF 6 ON 7 ON 8 ON DS2 1 OFF 2 OFF 3 ON 4 OFF 5 ON 6 OFF 7 ON 8 ON DS3 ALL ON Now look at your ...

Page 4: ...lass will show a bunch of number with the far left one flashing Press the change attendant button one time to clear The display should go to 50 Press the test button on the board continuously until the display reads 11d Once you see 11d stop pressing the button The display will change to 27 on the left and 001 on the right You must now go through the parameter and change the settings for each The ...

Page 5: ...73 0 61 1 81 1 If you do not have coin mechanics and you are hand pay only Parameter Setting 9 4 2 4 7 1 56 0 78lo 1 51 5000 58 1000 73 0 61 1 81 0 ...

Reviews: