43
BAE PD-VS-014-05
5.7.3
EtherNet/IP fieldbus
Device master data
To parameterize the correct Balluff SmartVision Controller model in an EtherNet/IP network, device database information
in the form of an EDS file is required.
The file is located on the Balluff homepage (see www.balluff.com).
Process data structure
The following values describe the data sizes of the input, output and configuration data. These must be entered in the
host system.
Assembly
Instance ID
Data length in Bytes
INPUT
100
256
OUTPUT
101
256
Input Assembly (input data, camera to PLC)
Start
byte
Length Description
0
64
Process data of 1st instance at
port 9000
The process data protocol is described in
"Fieldbus interface → Fieldbus protocol of Balluff
SmartVision Controller".
64
64
Process data of 2nd instance at
port 9001
128
64
Process data of 3rd instance at
port 9002
192
64
Process data of 4th instance at
port 9003
Output Assembly (output data, PLC to camera)
Start
byte
Length Description
0
64
Process data of 1st instance at
port 9000
The process data protocol is described in
"Fieldbus interface → Fieldbus protocol of Balluff
SmartVision Controller".
64
64
Process data of 2nd instance at
port 9001
128
64
Process data of 3rd instance at
port 9002
192
64
Process data of 4th instance at
port 9003
Summary of Contents for SmartVision BAE PD-VS-014-05