38
BAE PD-VS-014-05
Device name and IP address
The Balluff SmartVision Controller and the host system communicate via the PROFINET protocol. This means an IP ad-
dress and a unique device name are required. The device name and the IP address can be edited using the respective
project planning software used, e.g. “
Siemens TIA Portal
” and the IO device.
NOTE
The Balluff SmartVision Controller is delivered without a device name. The GSDML file has
the prepared device name "SVC01".
Configuration
In project planning for PROFINET devices, a device is mapped as a modular system that consists of a "SVC01" header
module and multiple data modules.
GSDML file
The device data required for project planning is stored in GSDML files (General Station Description). The data module of
the Balluff SmartVision Controller is represented slot-based in the project planning software. The GSDML file makes the
possible data modules (inputs/outputs for the Balluff SmartVision Controller) available. For the configuration of the Balluff
SmartVision Controller, the matching data modules are assigned to a specific slot.
•
Slot 0 must always be populated with the "SVC01" header module.
•
Slot 1 - 4 may host a data module for the Balluff SmartVision Controller.
Slot
Module
Function
0
Header module of SmartVision Controller
Parameter configuration, no process data
1
SmartVision Controller
Process data of 1st instance at port 9000
2
SmartVision Controller
Process data of 2nd instance at port 9001
3
SmartVision Controller
Process data of 3rd instance at port 9002
4
SmartVision Controller
Process data of 4th instance at port 9003
Integration into Project Planning Software
The connection of a Balluff SmartVision Controller to a Siemens S7 controller is shown with the “
Siemens TIA Portal
”.
The exact procedure depends on the project planning software used.