8
Online Adjust Mode
To enter
Online Adjust Mode
, press the
<PGM>
key for at least 3 seconds. Online Adjust Mode allows
you to set the Null, Gain and PWM Offset values.
Note - Due to possible voltage drops across the cables, the Null and Gain value should also be checked
at the input of the controller with a 6 digit multi-meter for accuracy. The voltage value on the display
represents the Analog Output Voltage seen directly on the Output of connector J1, pin “D”
1.
Adjust Null -
Locate the magnet to the Null location, towards the housing of the
transducer. The Null value may adjusted anywhere between -10 Vdc & +10 Vdc.
Press the
<UP>
key to increase the Null, press the
<DOWN>
key to decrease the
Null. The Analog Output Voltage is updated accordingly on the display. Press
<PGM>
to continue to the next parameter.
Note - If no transducer is detected on power up, the display will show 0.000 V
2.
Adjust Gain -
Locate the magnet to the Gain position, towards the end of the trans-
ducer rod (side that is away from the transducer housing). The Gain value may be
adjusted anywhere between -10 Vdc & +10 Vdc. Press the
<UP>
key to increase
the Gain, press the
<DOWN>
key to decrease the Gain
.
The Analog Output Voltage
is updated accordingly on the display. Press
<PGM>
to continue to the next pa-
rameter.
Note – If no transducer is detected on power up, the display will show 0.000 V
Note – It may be necessary to repeat the Online Adjust Mode steps 1 and 2 until the voltages re-
quired at the Null and Gain locations are set to desired values.
3.
Adjust PWM Offset
-
This step allows the pulse width of the PWM output signal to
be adjusted. To setup the PWM signal, locate the magnet at the NULL location.
Pressing the
<UP>
key will increase the pulse width of the PWM signal, pressing the
<DOWN>
key will decrease the pulse width. The PWM pulse width is updated ac-
cordingly on the display.
Note -
This step is not needed if only the analog output
is being used.
4. When
the
PWM
Offset
is properly set at the NULL point, press
<PGM>
to exit the
Online Adjust Mode and return to Run Mode.