6
To access the programming buttons and LCD display, remove 4 cover
screws and open the hinged cover.
Upon initial power up of the module, the display shows:
Version 1.xx subject to change without notice
The next screen shows the status of the transducer:
If no magnet is detected, the display will show No Transducer
Detected and the red error LED will be on.
Once the module has been powered and completed self testing, the
screen will look similar to the screen at right. Also, if the module and
transducer are working properly, both the green program LED and
the red error LED will be off.
Setup Instructions
Factory Default Settings
To enter the
Configure Mode
, press the
<PGM + DOWN
> keys simultaneously for at least 3 seconds.
Configure Mode allows the user to adjust the following parameters:
Adjust LCD contrast -
Press the
<UP> or <DOWN>
keys repeatedly to adjust
display contrast. Press
<PGM>
to continue to the next parameter.
Set Display Units -
For the LCD to display raw position values in Hexadecimal
(HEX), press the
<UP>
key for
System Units
. For the LCD to display raw posi-
tion in Decimal, press the
<DOWN
> key for
Normal
. Press the
<PGM>
key to
exit Configure Mode, and return to Run Mode.
1.
2.
Display Configuration Mode