BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Plessey Check Character Transmission
Enables/disables transmission of an MSI check character.
PLCT00(CR
Plessey Check Character Transmission =
Disable
CPLCT01(CR
Plessey Check Character Transmission =
Enable
DEFAULT
Plessey Length Control
This feature specifies either variable length decoding or fixed length decoding for the Plessey
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
PLLC00(CR
Plessey Length Control = Variable Length
CPLLC01(CR
Plessey = Fixed Length