Enter/Exit Programming Mode
4
Configuration Using Barcodes
Plessey
The following options apply to the Plessey symbology.
Plessey Enable/Disable
Enables/Disables ability of reader to decode Plessey labels.
DEFAULT
PLEN00CR)
Plessey = Disable
CPLEN01CR)
Plessey = Enable
Plessey Check Character Calculation
Enables/Disables calculation and verification of an optional Plessey check character.
PLCC00(CR
Plessey Check Character Calculation =
Disable
PLCC01(CR
Plessey Check Character Calculation =
Enable Plessey std. check char. verification
DEFAULT
PLCC02(CR
Plessey Check Character Calculation =
Enable Anker check char. verification
PLCC03(CR
Plessey Check Character Calculation =
Enable Plessey std. and Anker check char veri-
fication