www.balluff.com
11
english
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-3 to Tab. 4-4.
Note the information on shielding and cable
4.4.1 Connector S32/cable
Pin
Cable color
Interface
BTL7-P511…-S32
1
YE yellow
+Init
2
GY gray
+Start/stop
3
PK pink
–Init
4
RD red
Not used
1)
5
GN green
–Start/Stop
6
BU blue
GND
7
BN brown
10…30 V
8
WH white
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-3: Connection assignments
Fig. 4-9: Pin assignment of S32 (view from above on transducer),
8-pin M16 circular plug
4
Installation and connection (continued)
4.4.2 Connector S115
Pin
Interface
BTL7-P511…-S115
1
+Init
2
+Start/stop
3
–Init
4
Not used
1)
5
–Start/Stop
6
GND
7
10…30 V
8
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-4: Connection assignments
Fig. 4-10: Pin assignment of S115 (view from above on transducer),
8-pin M12 circular plug
BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _
Micropulse Transducer in a Profile Housing
Summary of Contents for BTL7-P511-M P-S32 Series
Page 1: ...Betriebsanleitung BTL7 P511 M_ _ _ _ P S32 S115 KA_ _ deutsch...
Page 2: ...www balluff com...
Page 25: ...User s Guide BTL7 P511 M_ _ _ _ P S32 S115 KA_ _ english...
Page 26: ...www balluff com...
Page 49: ...Manual de instrucciones BTL7 P511 M_ _ _ _ P S32 S115 KA_ _ espa ol...
Page 50: ...www balluff com...
Page 73: ...Notice d utilisation BTL7 P511 M_ _ _ _ P S32 S115 KA_ _ fran ais...
Page 74: ...www balluff com...
Page 97: ...Manuale d uso BTL7 P511 M_ _ _ _ P S32 S115 KA_ _ italiano...
Page 98: ...www balluff com...