20
english
Ignition protection
“ec” and “tb”
9
Resetting all values (reset)
NOTICE
Interference in function
Resetting the values while the system is running may
result in malfunctions.
►
Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
Displayed values (example)
At 0 to 10 V
At 4 to 20 mA
5.39 V
9.15 mA
Activate reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
10.50 V
3.60 mA
Reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
0.00 V
4.00 mA
After activation:
⇒
All values are reset.
9.89 V
19.13 mA
⇒
Current position value is displayed.
⇒
Reset is deactivated.
Abort reset
Resetting can be aborted without any changes
being saved after the
Activate reset
step.
►
Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
⇒
Current position value is displayed.
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-NEX-SR32/K_ _ _