18
english
Ignition protection
“ec” and “tb”
8
Adjusting
NOTICE
Interference in function
Adjustment while the system is running may result in
malfunctions.
►
Stop the system before performing adjustment.
Displayed values (example)
At 0 to 10 V At 4 to 20 mA
Initial situation:
– Transducer with magnet within measuring range
5.39 V
9.15 mA
Activate adjusting
►
Activate
b
for at least 4 s.
> 4 s
b
2.00 V
6.00 mA
⇒
Indication for adjustment is displayed.
⇒
The current position value is displayed again once
the button is released.
5.39 V
9.15 mA
Set start point
►
Bring magnet to the new start point.
1.04 V
4.82 mA
►
Activate
a
for at least 2 s.
> 2 s
a
⇒
The new start point is set with the last valid start
value.
0.00 V
4.00 mA
Adjust start value
►
The start value can be changed using
a
and
b
.
The gradient of the curve changes (see page 16).
0.00 V
4.00 mA
0.90 V
7.20 mA
►
End calibration procedure: Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
2.00 V
6.00 mA
⇒
Set position value is saved.
0.90 V
7.20 mA
For setting the end point, adjusting the end value,
and ending adjustment, see page 19.
Any of the individual steps for settings can be
selected. The adjustment process can be
ended at any time.
a
a
b
b
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-NEX-SR32/K_ _ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7-A M Series
Page 2: ...www balluff com ...
Page 4: ...www balluff com ...
Page 30: ...www balluff com ...
Page 56: ...www balluff com ...
Page 82: ...www balluff com ...
Page 108: ...www balluff com ...
Page 134: ...www balluff com ...
Page 159: ......