NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
The mounting surface of the transducer must make
f
full contact with the supporting surface.
The bore must be perfectly sealed (O-ring/support
f
ring).
The BTL transducer can be fastened in a fitting bore
(Ø 48 H8), but must be sealed with the provided O-ring
and support ring.
The body of the transducer is fastened using 3 M5
threaded pins at a 120° angle.
If installing horizontally with nominal lengths > 500 mm,
we recommend tightening the outer rod at the end (only
possible with Ø 10.2 mm) or supporting it.
If installed in a hydraulic cylinder, the magnet should not
make contact with the outer rod. Minimum bore diameter
in the support piston:
Tube diameter
Bore diameter
10.2 mm
At least 13 mm
8 mm
At least 11 mm
Square flange
20
5
3
M12x1
Ø 13.3
+0.10 -0.00
14
20
Ø 3.2
The square flange is included in the scope of
delivery.
Installation in hydraulic cylinders
Lead the M12 contact insert through the bore and out
1.
of the cylinder.
Position the square flange on the M12 contact insert
2.
and engage it.
Fasten the square flange to the hydraulic cylinder using
3.
4 screws. When installed, the connector complies with
protection category IP67.
Square flange
M12 contact insert
Installation
Mounting hole
Top view
Hydraulic cylinder
BTL6-A500/B50 _ -M _ _ _ _ -E2/E28-KA _ _/LA _ _-ZA0 _
Micropulse AT transducer in round profile housing