BTL5-A/C/E/G1_-M/U_ _ _ _-T-_S 32
Micropulse Linear Transducer - Rod Style
12
english
12
Versions (indicated on product label)
Supply voltage: 1 = DC 24 V
Electr. connection S 32: with connector
BTL5-A10-M0450-T-3S 32
No. of redundant systems:
2 = with two independent analog outputs
3 = with three independent analog outputs
Rod Style
,
Mounting:
T = metric thread M30×1.5
Nom. length (4 digits): M = metric in mm
U = inches in 1/10 Inch
Analog interface:
Voltage output
A10 =
0 ... 10 V
G10 =–10 ... 10 V
Current output
C10 = 0 ... 20 mA
C17 = 20 ... 0 mA
E10 = 4 ... 20 mA
E17 = 20 ... 4 mA
Reso hysteresis
= repeatability
Voltage
0.3 mV
Current
0.6 µA
Minimum
0.05 mm
Sampling rate f
Standard
= 2 kHz
Non-linearity
Nom. length < 500 mm > 500 mm
±300 µm
±0.06 % FS
Temperature coefficient 40 ppm/K
Shock loading
100 g/6 ms
per IEC 60068-2-27
1
Continuous shock 100 g/2 ms
per IEC 60068-2-29
1
Vibration
12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
(avoid resonant frequencies of the
transducer rod)
Pressure rating
up to 250 bar
when installed in hydraulic cylinder
1
Individual specifications as per Balluff
factory standard
11
Technical Data
Typical values at DC 24 V and 25 °C. Ready for operation at once, full accuracy after warm-up.
With magnet BTL-P-1028-15R. The values are for an individual measuring unit:
11.1
Dimensions, weight,
ambient
Nominal length
< 1000 mm
Dimensions
➥
➥
➥
➥
➥
Fig. 3-2
Weight approx. (1.5 kg +1 kg/m)
Housing
anodized aluminum
Pressure tube stainless steel 1.4571
Diameter
21 mm
Wall thickness 2 mm
E-modulus
approx. 200 kN/mm
2
Mounting thread M30×1.5
Operating temp.
–40 °C to +85 °C
Humidity < 90 %, non-condensing
Protection class
per IEC 60529 IP 67
when closed up
11.2
Supply voltage
(external)
Regulated voltage
BTL5-_1...
DC 20 to 28 V
Ripple
< 0.5 V
pp
Current draw
< 150 mA
Inrush per channel < 3 A/0.5 ms
Polarity reverse protection
built-in
Overvoltage protection
Transzorb protection diodes
Electric strength
GND to housing
500 V
11.3
Outputs
BTL5-A10...
Output voltage
0...10 V
Load current
< 5 mA
Ripple
< 5 mV
BTL5-G10...
Output voltage
–10...10 V
Load current
< 5 mA
Ripple
< 5 mV
BTL5-C1_...
Output current
0...20/20...0 mA
Load resistance
< 500 Ohm
BTL5-E1_...
Output current
4...20/20...4 mA
Load resistance
< 500 Ohm
11.4
Connection to controller
Analog interface: 1 connector S 32
per measuring unit, for shielded
cable (max. length, see Wiring),
Ø 6 to 8 mm
11.5
Included in shipment
Transducer
➥
➥
➥
➥
➥
Fig. 3-2
Calibration device
➥
➥
➥
➥
➥
Fig. 6-1
11.6
Magnet ring
(please order separately)
Magnet ring
BTL-P-1028-15R
Dimensions
➥
➥
➥
➥
➥
Fig. 3-4
Weight
approx. 68 g
Housing
anodized aluminum
Operating temp.
–40 °C to +85 °C
11.7
Accessories
(optional)
Connectors
➥
➥
➥
➥
➥
Fig. 4-3
No. 817 113 E
•
Edition 0110; Specifications subject to change.