www.balluff.com
1
english
BTL B/ZNC_ 00- _ _ _ _ -C15A _ _ _0-000S35
Magnetostrictive Linear Position Sensor – Rod Style
954925_AA ∙ DE ∙ E22; Änderungen vorbehalten.
The CE Mark verifies
that our products meet the requirements
of the current EU Directive.
Ø
10.2
25
0.5 Ø 25
34
60
X
41
Ø 45
12
M16
Thread size:
BTL B…: M18×1.5
BTL Z…: 3/4“-16UNF
Magnet
2)
Measuring length
Null point
End point
Mounting surface
Rod end
Type
X
Rod end
BTL _NC
A
…
30 −1 mm
with thread M4/4.5 deep
BTL _NC
E
…
2" −0.04"
with thread M4/4.5 deep
1) Unusable area
2) Not included in scope of delivery
1)
1)
S35
About this guide
This guide provides all the information required for the
installation and connection of the BTL magnetostrictive
linear position sensor with analog current and voltage
interface.
It applies to the following models:
–
BTL BNC_ 00- _ _ _ _ -C15A _ _ _0-000S35
–
BTL ZNC_ 00- _ _ _ _ -C15A _ _ _0-000S35
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Proper function according to the specifications in the
technical data is only assured when the product is used
solely as described in the user’s guide and the respective
documents as well as in compliance with the technical
specifications and requirements and only with suitable
original Balluff accessories.
Otherwise, there is deemed to be unintended use.
Unintended use is not permitted and will result in the loss
of warranty and liability claims against the manufacturer.
Reasonably foreseeable misuse
The product is not intended for the following applications
and areas and may not be used there:
– In safety-oriented applications in which personal safety
depends on the device function
– In explosive atmospheres
– In food applications
Other applicable documents
A comprehensive user’s guide and additional information
about this product can be found at
www.balluff.com
on
the product page.
Safety notes
Activities such as
installation
,
connection
and
commissioning
may only be carried out by qualified
personnel.
Qualified personnel
are persons whose technical
training, knowledge and experience as well as knowledge
of the relevant regulations allow them to assess the work
assigned to them, recognize possible hazards and take
appropriate safety measures.
The
operator
is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the product will not result in hazards to persons
or equipment.
The product must not be opened, modified or changed. If
defects and unresolvable faults occur in the product, take
it out of service and secure against unauthorized use.
Dimensions and function
To determine the position of a plant component, a magnet
is connected to the component. Together they are moved
along a waveguide located inside the BTL.