30
english
5.3
Optical Frontend
5.3.1 Description
The Optical Frontend delivers the measurement value
determined by the sensor.
The evaluation in the switching profiles is effected based
on this measurement value (see
on
5.3.2 Mathematics/Algorithm
Fig. 5-1:
Transducer V
alue
Received light energy
Taught-in 100% Reference
(=Received light energy from reflector
without object in beam path)
Mathematics/Algorithm
5.3.3 Process Data
Object ID
Name
Description
Direction
0xFFF7 (65527)
Transducer Value
Measurement value determined
Input
Tab. 5-4: Optical Frontend – Process Data
5.3.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Optical Frontend
0x01B2 (434)
0
R
4 bytes
Transducer Value
1
R
4 bytes
INT32
No
Tab. 5-5: Optical Frontend – ISDU
Transducer Value
Measurement value determined by the sensor.
Value
Description
0 (0x0000)
Measurement Range, Lower Limit
100 (0x0064)
Measurement Range, Upper Limit
Tab. 5-6: Transducer Value
5