36
english
5.4.2 Process Data (AdSS)
Object ID
Name
Description
Direction
0x0038 (56)
ADSS 1
AdSS Switching signal channel
Output
0x003E (62)
Teach IN
Manual teach-in trigger
Input
Tab. 5-8: Switching profiles – process data
5.4.3 Process Data (LSSC)
Object ID
Name
Description
Direction
0x003A (58)
LSSC 1
LSSC Switching signal channel 1
Output
0x003B (59)
LSSC 2
LSSC Switching signal channel 2
Output
0x003C (60)
LSSC 3
LSSC Switching signal channel 3
Output
0x003D (61)
LSSC 4
LSSC Switching signal channel 4
Output
0x003E (62)
Teach IN
Manual Teach-in Trigger
Input
Tab. 5-9: Switching profiles – process data
5.4.4 ISDU (AdSS)
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
SSC
Parameter
SP
0x0038 (56)
0
RW
16 bits
IntT16
No
0x000A (10)
SSC
Configuration
Logic
0x0039 (57)
0
RW
8 bits
UIntT8
No
0x01
Teach-in
Result
0x003B (59)
0
RO
8 bits
UIntT8
No
–
Tab. 5-10: Switching profiles – ISDU
SSC Parameter SP
This parameter represents the currently set switching point
(setpoint). The default setting is 0x000A.
SSC Configuration Logic
With the help of this parameter, the switching logic of the
switching channel can be configured.
Value
Meaning
Description
0x00 (0)
High Active
Switching logic
High
Active
0x01 (1)
Low Active
Switching logic
Low
Active
Tab. 5-11: Switching profiles – SSC Configuration Logic
5
Primary Device Functions (continued)
BOS R254K-UUI-LK10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LK10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LK10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LK10 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 112: ......
Page 113: ...BOS R254K UUI LK10 S4 Configuration Guide english...
Page 114: ...www balluff com...