www.balluff.com
9
5
Technical Data
5.1.
Dimensions
5.2.
Mechanical Data
Housing material
Die case zinc, matt nickel plated
Fieldbus
Profibus: M12, B-coded (female and male)
Supply power
5-pin
, 7/8“ (male)
I/O Ports
M12, A-coded (4 x female)
Enclosure rating
IP67 (only when plugged-in and threaded-in)
Weight
ca.: 352 g
5.3.
Electrical Data
Operating voltage
18 ... 30 V DC
Ripple
< 1 %
Current draw without load
≤ 200 mA
5.4.
IO-Link data
Baud rate
COM 1, 2, 3
Frame typ
1, 2.x, 3
5.5.
Operating
conditions
Operating temperature
Storage temperature
-5
C … 70°C
-25
C … 70°C
EMC
- EN 61000-4-2/3/4/5/6
- EN 55011
- Severity level 4A/3A/4B/2A/3A
- Gr. 1, Kl. A
Shock / vibration
EN 60068 Part 2-6/27