Balluff Network Interface Profibus
www.balluff.com
22
7
Startup
Example 3
Profibus IO-Link Master
Port 0
– 3 Pin 4: Configured as standard I/O port
Port 0
– 3 Pin 2: Configured as standard I/O port
Port 4 Pin 4: Configured as IO-Link port
Port 4 Pin 2: Configured as standard I/O port
Port 5 Pin 2+4: Configured as standard I/O port
Port 6 Pin 4: Configured as IO-Link port
Port 6 Pin 2: Configured as standard I/O port
Port 7 Pin 2+4: Configured as standard I/O port
Example of
„mixed configuration“
Byte Value
Meaning
Module
0
Station status
Norm parameters
1
WD_Fact_1
2
WD_Fact_2
3
MinTSDR
4
Indent_Number_High
5
Indent_Number_Low
6
Group_Intend
7
0x80 DPV1 Status 1
DPV1 parameters
8
0x00 DPV1 Status 2
9
0x00 DPV1 Status 3
10
0x0F Global diagnostic
Channel related diagnostic
Low voltage bus/sensor supply
Low voltage actuator supply
Head modules
11
0x00
Function Port 0 … 3 Pin 4
12
0x44
Function Port 4 … 5 Pin 4
13
0x44
Function Port 6 … 7 Pin 4
14
0x00
Function Port 0 … 3 Pin 2
15
0x00
Function Port 4 … 7 Pin 2
16
0x00
Safe state Port 0 … 3 Pin 4
17
0x00
Safe state Port 4 … 5 Pin 4
18
0x00
Safe state Port 0 … 3 Pin 2
19
0x00
Safe state Port 4 … 7 Pin 2
20
0x00 Parameter Server
Conflict Resolution
Download Enable
Upload Enable
21
0x10 Module Identifier / Validation type
IO-Link module
16 byte IN/16 byte Out
22
0x00 Cycle Time
23
0x00 Process data offset
24
0x10 Process data window length
25
0x00 Vendor ID 0
26
0x00 Vendor ID 1
27
0x00 Device ID 0
28
0x00 Device ID 1
29
0x00 Device ID 2
30
0xE0
Standard I/O
31
0x10 Module Identifier / Validation type
IO-Link module
16 byte IN/16 byte Out
32
0x00 Cycle Time
33
0x00 Process data offset
34
0x10 Process data window length
35
0x00 Vendor ID 0
36
0x00 Vendor ID 1
37
0x00 Device ID 0
38
0x00 Device ID 1
39
0x00 Device ID 2
40
0xE0