Balluff Network Interface EtherNet/IP
™
www.balluff.com
18
7
Display
7.5.
IP Configuration
1.
Long-time key press on set key starts editing mode.
2.
Configuration of the selected value by short-time key press on arrow-key
3.
After configuration store the new value by long-time keypress on set-key.
Note
To work with the new configuration, the module needs a power-down-reset.
Note
If a value has been changed, but the “old” address is still in use, the display shows
an “unequal” symbol.
7.6.
General
Information
Differences between new configuration and the configuration the module is working
with are shown by a unequal-symbol.
In editing mode the screen flashes
If the module receives a single ping, the word “ping” is shown in the display screen
for a few seconds. Afterwards the screen is reset to the screen which had been
shown before. By short-time key press on set key the ping-mode can be left
preterm.
The Led function at the display LEDs can be defined user specific by setting some
bits in the process data inputs.
(see “Process Data Outputs”)
The function plc-lock can also be used by setting a bit in the process data inputs.
(See “Process Data Outputs”)
Note:
Editing Mode can not be chosen in display if the plc lock bit in process data
inputs is set. (see “Process Data Outputs”)
001
005
S
S
005
editing mode