BMF 235
Sensor family
18
5
Teaching in switchpoints
Teach-In Status 0x003B (59)
The teach-in status can always be read out for verification.
Teach Flags
Teach State
SP2
SP1
TP2*
TP1*
TP2*
TP1*
0 = IDLE
1 = SP1 SUCCESS
2 = SP2 SUCCESS*
3 = SP12 SUCCESS*
4 = WAIT FOR COMMAND
5 = BUSY
6 = reserved*
7 = ERROR
*not supported, not required for Single Value Teach
Changing the hysteresis setting
S
BDCx
Hyst = 1
Hyst = 5
Hyst = 10
SP1
Direction
Access
Index
Subindex
BDC no.
Values
Comment
W
0x003D (61)
0x03
1
1…10
Standard value = 5
0x003F (63)
2
0x4001 (16385)
3
0x4003 (16387)
4
0x4005 (16389)
5
0x4007 (16391)
6
0x4009 (16393)
7
0x400B (16395)
8
5.2.7 Teaching in only one switchpoint
If only one switchpoint is required in a flexible production line:
1.
Temporarily place a permanent magnet on the sensor.
2.
Teach in the switchpoint that is not required (see „Manually teaching in switchpoints S1 and S2“ on page 10).
⇒
This will prevent a malfunction.