BIS V-6106 Ethernet/IP™
Processor Unit
86
7
Device
Functions
1
Cancel or
Enter
2
Enter (1 s)
3
Cancel (1 s)
Cancel (1 s)
Enter
(1 s)
Cancel
(1 s)
4
Enter
(1 s)
Cancel
(1 s)
7
Enter (1 s)
6
Enter (1 s)
5
Cancel (1 s)
Cancel (1 s)
Enter
(1 s)
Cancel (1 s)
8
Ź
You can switch through the positions (1st, 2nd, 3rd) by pressing Enter/Down.
The current position starts flashing.
Ź
Press Cancel/Up to increase the number at the currently selected position.
Ź
Press Enter (1 s) to confirm the configured gateway address octet and switch
to the next octet of the gateway address.
Ź
Press Enter (1 s) to confirm the configured gateway address in the 4th octet.
9
Enter (1 s)
10
Cancel (1 s)
Back to 3
Cancel (1 s)
Enter (1 s)
Back to 6
11
A device reset is carried out (after
restart: Back to 1)
Note
The display shows the currently set gateway address. An active gateway address is
indicated by a flashing network status LED. If a new gateway address is set by the
operator, the IP configuration will be set to a static address. The gateway address
consists of the IP address and associated subnet mask. The operator can only
change the octet at binary positions where a 0 was set in the subnet mask.
Configuring the
gateway address
BALLUFF
Main
IP Conf.
IP Set.
Main
IP Set.
Info
IP Setup
IP Addr.
Sub. M.
Gateway
192.168
002.001
IP Setup
Su. Ma.
Gateway
IP Setup
Su. Ma.
Gateway
Gateway
192
Save new
Gateway?
Setup
finished?
Device
Resets
now!