22
english
5.4
RFID Parameters
5.4.1 Description
With the RFID parameters, the behavior of the RFID
system can be configured:
– Persistent RFID parameters
– Temporary RFID parameters
– Diagnostic RFID parameters
The individual parameters are described in the operating
instructions.
5.4.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Persistent RFID parameters
0x0084 (132)
0
R/W
23 bytes
Record
Yes
–
Radio profile
1
R/W
4 bytes
UINT32
Yes
0x00000602
Initial Q-value
2
R/W
1 byte
UINT8
Yes
4
Max. EPC length
3
R/W
1 byte
UINT8
Yes
12
TID length
4
R/W
1 byte
UINT8
Yes
4
Session
5
R/W
1 byte
UINT8
Yes
0
Trext
6
R/W
1 byte
UINT8
Yes
1 (Trext on)
Modulation
7
R/W
1 byte
UINT8
Yes
1 (PR ASK)
Read transmitting power
(default)
8
R/W
2 bytes
INT16
Yes
11
Autom. increase of
transmitting power on write
9
R/W
1 byte
UINT8
Yes
8
Number of repetitions
10
R/W
1 byte
UINT8
Yes
5
Active channels
11
R/W
4 bytes
UINT32
Yes
0x0000000F
Activate BlockWrite
12
R/W
1 byte
UINT8
Yes
0 (off)
Max. write length
13
R/W
1 byte
UINT8
Yes
16
Max. read length
14
R/W
1 byte
UINT8
Yes
16
Automatic scanning
15
R/W
1 byte
UINT8
Yes
0 (off)
Auto. Scan resolution
16
R/W
1 byte
UINT8
Yes
50
Activate SafeMode
17
R/W
1 byte
UINT8
Yes
1 (on)
Temporary RFID parameters
0x0085 (133)
0
R/W
8 bytes
Record
No
–
Transmitting power on read
1
R/W
2 bytes
INT16
No
40
Access password
2
R/W
4 bytes
UINT32
No
0x0000
Auto setup state
3
R/W
1 byte
UINT8
No
0
Memory bank
4
R/W
1 byte
UINT8
No
3
Diagnostic RFID parameters
0x0088 (136)
0
R
9 Byte
Record
n/a
–
AutoSelect
1
R
1 byte
UINT8
n/a
60
Tag PC
2
R
6 bytes
UINT8[]
n/a
0x0000
Temperature Amplifier
3
R
2 bytes
UINT16
n/a
0
Tab. 5-4: RFID parameters – ISDU