HF-SERIES REFERENCE MANUAL
60
3
3.1.6 BIS M-628-075-A01-03-ST34 PROFINET Models
LED Name
LED Color
LED Description
READY
GREEN
The READY LED is ON after the power up
sequence has completed.
RF
AMBER
The RF LED illuminates when RF power is
being transmitted by the antenna.
COM
AMBER
The COM (communications) LED flashes ON
and OFF when data is being transmitted
between the antenna and a tag.
When in Continuous Read mode, the COM LED
will remain ON and will turn OFF briefly only
while data is being read from or written to a tag.
MOD
STATUS
GREEN/RED
SOLID GREEN:
initialized, Normal Operation
FLASHING GREEN (1 FLASH):
diagnostic
event(s) present.
FLASHING GREEN (2 FLASHES):
blink used
for node identification
SOLID RED:
exception error
FLASHING RED (1 FLASH):
configuration
error
FLASHING RED (2 FLASHES):
IP address
error
FLASHING RED (3 FLASH):
Station Name
error
FLASHING RED (4 FLASHES):
Internal error
NET
STATUS
GREEN
SOLID GREEN:
IO Controller connected in
RUN
FLASHING GREEN:
IO Controller connected in
STOP
LINK 1
LINK 2
AMBER
SOLID AMBER:
Profinet link established
Summary of Contents for BIS M-62 Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...