BIS M-62_ MANUAL
148
9
After the Master acknowledges that it has received the fragment, the Slave places the next
fragment in the Input Buffer and toggles
Bit 0
of the
IBCB
&
IBDCB
.
Since this is still not the last fragment, the Save leaves
Bit 3
set to 1 in the
IBCB
&
IBDCB
(See the
Green
changes below)
Output Buffer
Input Buffer
Byte #
Value
Byte #
Value
00:
83
Output Buffer Control Byte
(OBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0] [0] [0] [1] [1]
00
8A
Input Buffer Control Byte
(IBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0] [1] [0] [1]
[0]
01:
00
(Always 0)
01:
00
(Always 0)
02:
0C
(Packet length in bytes)
02:
1C
(Packet length in bytes)
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
..
30:
00
06
AA
05
00
01
03
E8
00
00
00
32
00
00
00
00
00
00
..
00
(CBx Command word length MSB)
(CBx Command word length LSB)
Minimum of 6 words
(CBx Command Type) Always AA
(CBx Command Opcode)
0x05 = Read Tag Data
(CBx Command, byte not used)
(CBx Command “Node ID”)
(CBx Command Timeout MSB)
(CBx Command Timeout LSB)
0xE8 = 1000 ms timeout
(CBx Command Start Address MSB)
(CBx Command Start Address LSB)
address 0
(CBx Command Length MSB)
(CBx Command Length LSB)
50 bytes
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
(CBx Response Data Byte 17)
(CBx Response Data Byte 18)
(CBx Response Data Byte 19)
(CBx Response Data Byte 20)
(CBx Response Data Byte 21)
(CBx Response Data Byte 22)
(CBx Response Data Byte 23)
(CBx Response Data Byte 24)
(CBx Response Data Byte 25)
(CBx Response Data Byte 26)
(CBx Response Data Byte 27)
(CBx Response Data Byte 28)
(CBx Response Data Byte 29)
(CBx Response Data Byte 30)
(CBx Response Data Byte 31)
(CBx Response Data Byte 32)
(CBx Response Data Byte 33)
(CBx Response Data Byte 34)
(CBx Response Data Byte 35)
(CBx Response Data Byte 36)
(CBx Response Data Byte 37)
(CBx Response Data Byte 38)
(CBx Response Data Byte 39)
(CBx Response Data Byte 40)
(CBx Response Data Byte 41)
(CBx Response Data Byte 42)
(CBx Response Data Byte 43)
(CBx Response Data Byte 44)
31:
83
Data Consistency Byte (OBDCB)
31:
8A
Data Consistency Byte (IBDCB)
Summary of Contents for BIS M-62 Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...