background image

www.balluff.com 

   

   

  1 

Content 

1

 

User instructions 

3

 

1.1.

 

Validity of the Guide 

3

 

1.2.

 

Typographical Conventions 

3

 

Enumerations 

3

 

Syntax 

3

 

Cross references 

3

 

1.3.

 

Symbols 

3

 

1.4.

 

Abbreviations 

3

 

1.5.

 

Differing views 

3

 

2

 

Safety 

4

 

2.1.

 

Proper Use 

4

 

2.2.

 

Authorized Personnel 

4

 

2.3.

 

Obligations of the Operating Company 

4

 

2.4.

 

Malfunctions 

4

 

2.5.

 

Meaning of the Warning Notices 

4

 

 

4

 

2.6.

 

Certification 

4

 

3

 

Construction and Function 

5

 

3.1.

 

Construction 

5

 

3.2.

 

Function 

5

 

3.3.

 

Features, Advantages 

5

 

3.4.

 

Indicators 

5

 

4

 

Function indicator and diagnosis 

6

 

4.1.

 

Base indicators 

6

 

4.2.

 

Remote indicators 

6

 

5

 

Installation and Connection 

7

 

5.1.

 

Mutual Interference 

7

 

5.2.

 

Installation in Metal 

7

 

5.3.

 

Angular offset 

7

 

5.4.

 

connection 

8

 

5.5.

 

Series connection 

8

 

6

 

Technical Data Base 

9

 

6.1.

 

Dimension 

9

 

6.2.

 

Mechanical data 

9

 

6.3.

 

Operating conditions 

9

 

6.4.

 

Electrical data 

9

 

6.5.

 

Electrical connection 

9

 

7

 

Technical Data Remote 

10

 

7.1.

 

Dimension 

10

 

7.2.

 

Mechanical data 

10

 

7.3.

 

Operating conditions 

10

 

7.4.

 

Electrical data 

10

 

7.5.

 

Electrical connections M12, 5-pin, socket 

10

 

8

 

IO-Link communication 

11

 

8.1.

 

Process data 

11

 

8

 

IO-Link-communication 

12

 

8.2.

 

Parameters 

12

 

8.3.

 

Events 

12

 

Event 1 

12

 

Event 2 

12

 

9

 

Accessories 

13

 

9.1.

 

Connectors 

13

 

9.2.

 

Installation accessories 

13

 

9.3.

 

Active components 

13

 

Summary of Contents for BIC 2I0-IAA50-M30MI3-SM4A5A

Page 1: ...BIC IO Link unidirectional 500 mA IP67 11 bytes User s Guide...

Page 2: ...is 6 4 1 Base indicators 6 4 2 Remote indicators 6 5 Installation and Connection 7 5 1 Mutual Interference 7 5 2 Installation in Metal 7 5 3 Angular offset 7 5 4 connection 8 5 5 Series connection 8 6...

Page 3: ...Balluff Network Interface www balluff com 2 10 Type Designation Code 14 10 1 Type Code 14 10 2 Order code 14...

Page 4: ...tions Enumerations are shown as a list with bullet points Entry 1 Entry 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the addition...

Page 5: ...cannot be rectified the device must be taken out of operation and protected against unauthorized use 2 5 Meaning of the Warning Notices The warning notices in this guide and the measures described fo...

Page 6: ...e energy available for the IO Link device is dependent on the distance and on the offset between base and remote and is therefore limited For this reason the total current consumption of the connected...

Page 7: ...flashing inversely IO Link communication between master and base is OK Red flashing No remote detected Red off Remote present IO Link communication OK Red static Remote present no IO Link communicati...

Page 8: ...tallic objects on the coil cap cause the objects to be heated Install the components so that no metallic objects can collect on the coil cap There is a fire hazard When installing in metal the specifi...

Page 9: ...ger than 20 m 5 5 Series connection Two BIC systems can be connected in series Caution This cuts the power in half from 500 mA to 250 mA The cable length between the individual components in each case...

Page 10: ...t Approx 160 g Tightening torque 70 Nm 6 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C 6 4 Electrical data Supply v...

Page 11: ...wed down state Connection type M12 A coded Cable PUR Dimensions D x L in mm M30 X 106 Weight Approx 160 g Tightening torque 70 Nm 7 3 Operating conditions Transmission distance 1 to 5 mm Operating tem...

Page 12: ...g unused bytes are transmitted with 0 Bytes 0 to 9 7 6 5 4 3 2 1 0 Process data of the connected IO Link devices Byte 10 7 6 5 4 3 2 1 0 Not used Not used Not used Not used Status Supply remote Status...

Page 13: ...x 050602 0 x 0A 0 x 0B 0 x 10 0 Vendor name 7 bytes BALLUFF 0 x 11 0 Vendor text 15 bytes www balluff com 0 x 12 0 Product name 37 bytes BIC 1I0 IAA50 M30MI3 SM4A4A 0 x 13 0 Product ID 7 bytes BIC0053...

Page 14: ...cable length PUR for remote open cable end BCC M415 0000 1A 003 PX0434 xxx XXX cable length 9 2 Installation accessories Description Description Fig BES 30 0 BS 1 BES 30 HW 1 9 3 Active components De...

Page 15: ...Balluff inductive Coupler Base 1 Remote 2 Technology PNP variant 24 V power class 500 mA IA 11 bytes Housing shape M30x1 5 Housing material M brass and length SM4A5A Connector M12 axial Number of pin...

Page 16: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 07158 173 0 Fax 07158 5010 balluff balluff de Nr 885425 726 E 04 127519 Edition L18 Replaces Edition 1203 Subject...

Reviews: