Balluff Inductive Coupler
Base BIC 1I0-IAA50-M30MI3-SM4A4A and
Remote BIC 2I0-IAA50-M30MI3-SM4A5A
Remote BIC 2I0-IAA50-M30MI3-BPX04-002-M45A
www.balluff.com
6
4 Function indicator and diagnosis
4.1. Base indicators
Signaling
Function
Green, static
Supply voltage OK
No IO-Link communication
Green, flashing inversely
IO-Link communication between master and base is OK
Red, flashing
No remote detected
Red off
Remote present, IO-Link communication OK
Red, static
Remote present, no IO-Link communication
to connected device
4.2. Remote
indicators
Signaling
Function
Green – static
The remote is located within the working range of a base,
communication between the remote and IO-Link device is
OK
Green, flashing
No IO-Link device present
Green LED status indicator "IO-Link
Green LED status indicator