BIC 1B0-ITA50-Q40KFU-SM4A4A
BIC 1B0-IT005-Q40KFU-SM4A4A
BIC 2B0-ITA50-Q40KFU-SM4A5A
User´s Guide
Page 1: ...BIC 1B0 ITA50 Q40KFU SM4A4A BIC 1B0 IT005 Q40KFU SM4A4A BIC 2B0 ITA50 Q40KFU SM4A5A User s Guide...
Page 2: ...ng the holder 7 4 Energy Transfer 8 4 1 Derating 8 Derating curve output power of the remote at 24V 5 8 Note 8 4 2 Reduction of the power emitted at the base when the remote is disconnected 8 Technica...
Page 3: ...Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device is a piece of equipment...
Page 4: ...e reference values of the EU council recommendation 1999 519 EC EN 62311 2008 and has to be ensuring as value for safety of human exposure to electromagnetic fields It s possible that for people with...
Page 5: ...data see previous picture from the IO Link master to the BIC system component remote In this way the IO Link functionality of the IO Link port on the master is made available without contact on the r...
Page 6: ...Device damage due to induction effects Metallic objects on and in front of the coil cap will be heated The active area is characterized by the cross hairs on the body See figure chapter 3 1 The compo...
Page 7: ...BIC 2B0 ITA50 Q40KFU SM4A5A Remote www balluff com 6 3 Installation 3 3 Distances offset Permitted distances offset of the axes Type A mm B mm BIC 1B0 ITA50 Q40KFU SM4A4A 5 5 BIC 2B0 ITA50 Q40KFU SM4...
Page 8: ...nsert is rotated step 7 subsequent reassembly is performed in reverse order Removing the holder 1 Loosen the grub screw 2 Pull off the BIC holder 3 Loosen the two countersunk screws 4 Remove the BIC b...
Page 9: ...tput power of the remote at 24V 5 Note The measurement on which the derating curve is based was carried out without axis and angular offset The value ranges of the derating curve are to be interpreted...
Page 10: ...from the IO Link port on the master to the IO Link device 5 2 Connection time The time needed to establish the connection of base and remote is affected by many different variables Start up speed and...
Page 11: ...ply voltage OK Green inverted flashing IO Link connection OK LED 2 Yellow flashing No Remote found Yellow static Remote found Red flashing Undervoltage Mechanical data Housing material Black plastic P...
Page 12: ...Electrical data Supply voltage 24 V DC 10 by EN 61131 2 Current consumption 1 4 A Standby current 200 mA Overload protection Yes Ripple 1 Pin Assignment Power M12 4 pin socket PIN Signal 1 24 V 2 Tran...
Page 13: ...ed flashing IO Link connection OK LED 2 Yellow on Pin 2 high Yellow off Pin 2 low Mechanical data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed...
Page 14: ...www balluff com 13 6 Technical data Pin Assignment Power M12 5 pin connector PIN Signal 1 24 V 2 Transparent output 3 GND 0V 4 C Q IO Link 5 NC...
Page 15: ...IT005 Q40KFU SM4A4A Base BIC 2B0 ITA50 Q40KFU SM4A5A Remote www balluff com 14 7 Order information Ordering information Product ordering code Ordering code BIC 1B0 ITA50 Q40KFU SM4A4A BIC0070 BIC 1B0...
Page 16: ...ww balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 898544 E 726 06 127436 Edition K18 Replaces Edition K14 Subjec...