background image

Model: 

 

 

 

 

 

 

 

 

BF-IDM11 

 

 

Operating Guide  

RFID Reader  

 

Setup and Operation 

 
For operation of BF-IDM11 Readers a IO-Link Master device is needed. The Master is used as 
gateway between higher level controllers and RFID Reader. 
 

Status Indicators 

 
The device will show its status using the 2 LEDs at the corners of the housing. In normal 
operation state the meaning of these lights are as follows: 
 

► 

Green light "Power" indicates that the device is connected to the processor unit and ready to 

operate. 

► 

Orange light "Tag present" indicates that a RFID tag has been detected in front of the 

transceiver coil. 
 

Electrical Data 

 
Operating voltage (nominal) 

+24 V DC 

Current draw (at +24 V DC) 

≤ 200 mA 

Operating Frequency 

13.56 MHz 

Active principle 

Magnetic field 

Transmit power 

Class 5 

 

Mechanical Data 
 

Housing Material 

Metal / ABS-GF16 / PBT / PA12-GF30 

Weight max. 

400g 

Ambient temperature 

0…+70°C 

 