Instruction manual BES M30MF2-PSC10B-BV02-EXE
Instruction manual BES M30MF2-PSC10B-BV02-EXE
BA-S36073-GB-2018-28
BA-S36073-GB-2018-28
Page 3
Page 2
nicht explosionsgefährdeter
Bereich
non hazardous area
explosionsgefährdeter
Bereich (Gas oder Staub)
hazardous area (gas or dust)
IGEX22c...
L+
S
L–
BN
BK
BU
BES...-EXE
54 44
LED
M30x1,5
36
8
betriebsmäßig geerdeter
metallischer Montagerahmen /
grounded metal frame
Bauform /
type
max. Drehmoment /
max. torque
M12x1
M18x1
M30x1,5
10 Nm
25 Nm
40 Nm
IECEx Certificate
IECEx EPS 18.0030X
Ignition protection type (ATEX): Gas-Ex
II 3G Ex ec IIC T6 Gc
Dust-Ex
II 3D Ex tc IIIC T70°C Dc
Ignition protection type (IECEx): Gas-Ex
Ex ec IIC T6 Gc
Dust-Ex
Ex tc IIIC T70°C Dc
Temperature range in T6 (Zone 2)
–20 °C ≤ Ta ≤ +60 °C
Temperature range in T5 (Zone 2)
–20 °C ≤ Ta ≤ +60 °C
Temperature range in T4 (Zone 2)
–20 °C ≤ Ta ≤ +60 °C
Temperature range in T3 (Zone 2)
–20 °C ≤ Ta ≤ +60 °C
Temperature range dust-Ex (Zone 22)
–20 °C ≤ Ta ≤ +60 °C
Maximum surface temperature (Zone 22)
70 °C
Rated Voltage
30 V DC
Supply voltage
24 V DC ±10%
Rated current
100 mA DC
Switching current
100 mA DC
Electrostatic chargeable plastic housing
With reference to group II (gas):
603 mm²
With reference to group III (dust):
930 mm²
Housing material
Br-Ni / PA
Switching output
PNP-Normally open
Switching distance Sn
10 mm flush
Operating point
0.8 Sn
Hysteresis
< 0.1 Sn
Switching frequency
300 Hz
Test voltage
500 V / 50 Hz / 60 s
Degree of protection [EN 60529]
IP 67
Electrical connection
2 m PUR-cable, grey 3x0.34 mm²
Accessories
2x nut M30x1.5, Br-Ni
Dimensions
Connection diagram
Technical data
Installation
Colour code BK: black | BN: brown | BU: blue | GY: grey | WH: white
Trouble shooting
Scope of delivery, transportation and disposal
• Inspect packaging and content for damage.
• Check the delivery for completeness.
• Disposal note: Do not dispose the device in the domestic waste, comply with relevant laws and national regulations.
Failure
Cause of failure
Remedy
The functioning indicator does not light
up when the proximity switch is actuated
Supply voltage too low or
not connected
Check power supply
No change of
switching signal
Operation of the proximity
switch outside of specification
Check range of application
of the proximity switch