www.balluff.com
31
Continuation „
Serial Menu
“:
SERIAL PROTOCOL
Determines the sequence of characters send, when using the serial output for cyclic data
transmission under time control (xxxxxxx = value SERIAL VALUE).
Setting „1“ removes the unit address from the string which allows a slight faster transmission
cycle.
0
Transmission report = Unit Nr., +/-, data, LF, CR
1
1 +/- X
X
X
X
X
X
X
LF CR
1
Transmission report = +/-, data, LF, CR
+/- X
X
X
X
X
X
X
LF CR
SERIAL TIMER (S)
This register determines the cycle time in seconds for cycling transmission of
SERIAL VALUE
when
using the serial output. (On a serial request, the cycling transmission is stopped for 20 s)
0,000
All cyclic transmission is switched off. The unit will send data upon a serial
request or with command SERIAL PRINT.
…
60,000
Cycle time in seconds.
SERIAL VALUE
This parameter defines the value to be transmitted.
Einstellung
Code Bedeutung
0
:0 Measurement_Result (Result after linking, scaling, filter, etc.)
1
:1 Analog_Out_Voltage (Analog output modulation (in mV))
2
:9 Minimum_Value (Minimum value of Measurement_Result)
3
;0 Maximum_Value (Maximum value of Measurement_Result)
4
;1 Analog_Out_Current (Analog output modulation (in µA))
5
;2 Analog_Out_Percentage (Percentage analog output level)
(Measurement result in xxx.x %)
6
;3
Error Status (Reading the error code)
7
;7
Actual Position (Start Stop: position [in µm]
with offset without
scaling)
8
;9
Raw Position (Start Stop: position [in µm] without Offset and
without scaling))