Menu structure (continued)
8.4
Adjust
ADJUST
ADJ Adjust
Adj.SSC1
SC1 Adjust SSC1
SSC1 Logic LOG HighActive*, Low Active
Hysteresis
HYS 3%, 6%, 12%*, 25%
Int.Time
INT
Integration Time: 4..32*..256 ms
Ampl.Mode AMD Auto.Ampl.*, Man.Ampl.
1PT-Offset
OFS Offs.neg.*, Offs.pos., no Offset
TeachStor.
STO permanent*/temporar
Delay 1
DL1 Adjust Delay Out1
Delay Mode MOD Del:Off*, Del:Delay, Del:OneSh.
Off-Delay
OFD 0*..10000 ms
On-Delay
OND 0*..10000 ms
Adj.SSC2
SC2 Adjust SSC2
SSC2 Logic LOG HighActive*, Low Active
Hysteresis
HYS 3%, 6%, 12%*, 25%
1PT-Offset
OFS Offs.neg.*, Offs.pos., no Offset
TeachStor.
STO permanent*/temporar.
Delay 2
DL2 Adjust Delay Out2
Delay Mode MOD Del:Off*, Del:Delay, Del:OneSh.
Off-Delay
OFD 0*..10000 ms
On-Delay
OND 0*..10000 ms
8.4.1 Adjust SSC1 und SSC2
SSC Logic:
* High active / Low active
Switchpoint Hysteresis: * 3%, 6%, 12% (default), 25%
Hysteresis in Single Point Mode always negative, switching
points: SP1 and SP1 - Hysteresis
Hysteresis in Window Mode symmetrical, switching points:
SP1 + 1/2 hysteresis,
SP1 - 1/2 hysteresis,
SP2 + 1/2 hysteresis,
SP2 - 1/2 hysteresis
In Two-Point-Mode no hysteresis, switching points: SP1
and SP2
Integration Time
Determines the time interval of the averaging for the auto-
matic tracking of the switching thresholds.
Used only in Dynamic and Threshold Tracking Modes.
The value for the integration time should be selected at
least 3 times higher than the signal duration of the event.
(e.g. node in a fast moving thread).
Automatic Teach Amplification
Value
Description
Auto.Ampl.
The amplification is automatically
adjusted during the teach process
Man.Ampl.
(always “off” for SSC2)
Tab. 8-3: Adjust – Automatic Teach Amplification
The “Automatic Teach Amplification” is only used when
teaching SP1, SP1TP2 and
SP2TP2.
Single Point Offset
Only used for Single-Value-Teach in Single-Point-Mode.
In Window or Two-Point-Mode the offset is not applied.
Value
Meaning
Description
No offset
no offset
for edge teach
Offs.neg.
negative offset
(2 x hysteresis)
DL or RL object
Offs.pos.
positive offset
(3 x hysteresis)
Background
Tab. 8-4: Adjust – Single Point Offset
Teach Storage
Value
Meaning
Description
permanent permanent
The teach result is stored
permanently
Temporar.
temporary
The teach result is stored
until the next restart
Tab. 8-5: Adjust – Teach Storage
The temporary Teach Storage Mode should be used when
teaching more than 50 times a day.
8.4.2 Signal Delay
Description
This is a function that is applied to an internal binary signal.
This function allows the user to apply time delay functions
to the internal binary signal of the device (On-Delay, Off-
Delay, One-Shot or On/Off-Delay).
Mathematics/Algorithm
Fig. 8-26: Signal Delay – Mathematics/Algorithm
BAE SA-OH-059-YI-----
Photoelectric Sensors
Summary of Contents for BAE SA-OH-059-YI-DP02
Page 1: ...deutsch Betriebsanleitung english User s guide BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G...
Page 2: ...www balluff com...
Page 3: ...BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 32: ......
Page 33: ...BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G User s Guide english...
Page 34: ...www balluff com...