2

english

Safety notes

Installation 

and 

startup

 may only be performed by 

trained specialists with basic electrical knowledge.

Qualified personnel

 are persons whose technical 

training, knowledge and experience as well as knowledge 

of the relevant regulations allows him to assess the work 

assigned to him, recognize possible hazards and take 

appropriate safety measures.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the measuring system 

will not result in hazards to persons or equipment.

If defects and unresolvable faults occur in the signal 

converter, take it out of service and secure against 

unauthorized use.

General safety notes

Turn off power to the system before connecting the signal 

converter.

Always observe the safety instructions in this guide and the 

measures described to avoid hazards.

Display and operating elements

Fig. 2: 

Potentiometer

4 × green LED

Yellow LED, relay

Red LED

Display and operating elements

Element

Function

Green LED

On when the set limit value is exceeded.

Yellow LED

On when the set limit value is reached.

Red LED

On when the set limit value is undershot.

Potentiometer Setting the limit:

–  Turning clockwise results in a lower 

limit value.

–  Turning counter-clockwise results in a 

higher limit value.

Fig. 3:  Wiring diagram

Electrical connections

Terminal  

(see Fig. 2)

Sensor with switching output

1

Connection to flow controller 

BFF T_ _ _ _-_ _002-_ _ _A0A-S4

2
3
4
5

Relay NO

6
7

8

Supply –

Signal converter for screw-in flow controllers

BAE SA-FF-055-RS

Summary of Contents for BAE SA-FF-055-RS

Page 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation italiano Manuale d uso espa ol Manual de instrucciones BAE SA FF 055 RS...

Page 2: ...www balluff com...

Page 3: ...nicht in explosionsgef hrdete Bereiche verlegt werden Das Auswerteger t ist eine Standardkomponente und keine Sicherheitseinrichtung nach MRL 2006 42 EG F r Sicherheitsapplikationen ist eine detaillie...

Page 4: ...zu sichern Allgemeine Sicherheitshinweise Vor Anschluss des Auswerteger ts die Anlage spannungs frei schalten Beachten Sie unbedingt die Sicherheitshinweise in dieser Anleitung und die beschriebenen...

Page 5: ...n Der Relaiskontakt ist geschlossen wenn die gelbe LED leuchtet Schaltpunkt mit dem Potenziometer in der Frontseite des Ger ts einstellen Str mungsgeschwindigkeit und Mediumtemperatur w h rend der Ein...

Page 6: ...ereich Erfassungsbereich Abh ngig von Durchflussw chter Umgebungsbedingungen Lagertemperatur 20 60 C Schutzart IEC 60529 IP40 Schutzart Schraubklemmen IP20 Umgebungstemperatur 20 60 C Fehlerbehebung F...

Page 7: ...eas The signal converter is a standard component and not a safety device per MRL 2006 42 EG For safety applications a detailed assessment of the applicability of the sensor including signal converter...

Page 8: ...against unauthorized use General safety notes Turn off power to the system before connecting the signal converter Always observe the safety instructions in this guide and the measures described to avo...

Page 9: ...ay contact is closed when the yellow LED is on Set the switchpoint using the potentiometer on the front side of the device Keep the flow rate and medium temperature stable while setting and wait until...

Page 10: ...n range measuring range Detection range Depends on flow sensor Ambient conditions Storage temperature 20 60 C IP rating per IEC 60529 IP40 Screw terminal IP rating IP20 Ambient temperature 20 60 C Tro...

Page 11: ...composant standard et n est pas un dispositif de s curit au sens de la norme MRL 2006 42 CE En raison de la conception de l installation une valuation d taill e de la possibilit d utilisation du capte...

Page 12: ...nsignes g n rales de s curit Mettre l installation hors tension avant le raccordement de l unit d exploitation Respecter imp rativement les consignes de s curit de cette notice et les mesures d crites...

Page 13: ...n ralit s Le contact de relais est ferm lorsque la LED jaune est allum e R gler le point de commutation l aide du potentiom tre situ l avant de l appareil Maintenir stables la vitesse d coulement et l...

Page 14: ...tion plage de mesure Plage de d tection D pend du d bitm tre Conditions ambiantes Temp rature de stockage 20 60 C Classe de protection CEI 60529 IP40 Classe de protection bornes vis IP20 Temp rature a...

Page 15: ...onente standard e non un dispositivo di sicurezza secondo la Direttiva Macchine 2006 42 CE Per le applicazioni di sicurezza nella progettazione dell impianto necessaria una valutazione dettagliata del...

Page 16: ...tro l uso non autorizzato Indicazioni di sicurezza generali Prima di collegare il dispositivo di analisi togliere tensione all impianto Seguire scrupolosamente le avvertenze di sicurezza del presente...

Page 17: ...Il contatto del rel chiuso quando il LED giallo si accende Regolare il punto di commutazione con il potenziometro nella parte frontale del dispositivo Durante la regolazione mantenere stabili la veloc...

Page 18: ...mpo di rilevamento In base al flussostato Condizioni ambientali Temperatura di magazzinaggio 20 60 C Grado di protezione IEC 60529 IP40 Grado di protezione morsetti a vite IP20 Temperatura ambiente 20...

Page 19: ...est ndar y no es ning n dispositivo de seguridad seg n MRL 2006 42 CE Para aplicaciones de seguridad se requiere una evaluaci n detallada de la posibilidad de empleo del sensor junto con el aparato d...

Page 20: ...dad generales Dejar la instalaci n sin tensi n antes de conectar el aparato de evaluaci n Es indispensable que tenga en cuenta las indicaciones de seguridad que figuran en este manual y las medidas qu...

Page 21: ...o de conmutaci n con el potenci metro en el lado frontal del aparato Mantener constantes la velocidad de flujo y la temperatura del medio durante el ajuste y esperar la compensaci n de temperatura ent...

Page 22: ...ci n En funci n del caudal metro Condiciones ambientales Temperatura de almacenamiento 20 60 C Grado de protecci n IEC 60529 IP40 Grado de protecci n de los bornes roscados IP20 Temperatura ambiente 2...

Page 23: ......

Page 24: ...e KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shanghai 200127 P R...

Reviews: