INSTALLATION
19
2
2.6.2 Installing the BIS M-41_ RS485
Figure 17 - RS485 Typical Layouts
The BIS M-41_-067-001-04-S92 Compact processor is designed for Subnet16™ RFID
applications, where the compact processor is connected in an RS485 network via
Subnet16™-compatible cables to the host through a Gateway or Hub.
1. To mount the BIS M-41_ Compact processor:
a) For the BIS M-410 Compact processor, attach to the polycarbonate mounting bracket
(for metallic isolation) using the two sets of M4 screws, washers and nuts provided as
shown in
. Fasten the other end of the mounting bracket to your work area.
Tighten all screws to 0.7 Nm (6 lbs per inch).
b) For the BIS M-411 Compact processor, fasten it to the mounting surface using two
M5 (#10) screws, washers and nuts (not provided). Tighten all screws to between 1.3
and 1.7 Nm (12-15 lbs per inch).
2. Attach a Subnet16™ compatible cable (i.e. BCC0ET0) to the M12 5-pin male Subnet16™
connector on the compact processor. Connect the other end of this cable to your
Subnet16™ network.
3. To complete the Subnet16™ network installation, including power supply wiring, trunk
wiring, network termination, Gateway/Hub wiring, and for a complete list of compatible
accessory cables and Subnet16™ network layout examples, see the Subnet16™
Gateway or Subnet16™ Hub Manuals.
After installation, the Subnet16™ network can be configured through the Subnet16™
Gateway/Hub using the Balluff Dashboard™ Configuration Tool. See the Dashboard™
Configuration Tool Manual for details.
BCC07WR
B
C
C
0
9MR
to
Configuration PC
to Power Supply
VDC GND
BCC0ET0
BC
C
0
ET
0
BC
C
0
ET
4
BIS M-411
BIS M-410
Gateway
to Host
BCC07WR
BCC07WR
BCC0ET0
BIS M-411
BC
C
0
ET
0
BC
C
0
ET
0
BC
C
0
ET
J
BCC0ET0
BCC07WR
B
C
C
0
9MR
Summary of Contents for BIS M-41 Series
Page 1: ...BIS M 41_ Processor Unit Technical Description Manual...
Page 2: ......
Page 8: ...OVERVIEW 1 1...
Page 41: ......
Page 43: ......
Page 44: ...1 Nr 896 711 E Edition 1305 Subject to modification...