Cooling mode
Test system
pressure.Does the low
pressure normal at
service part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.Does the low
pressure nomal over
again?
Air remaining at the
refrigerant system.
yes
The system wants
refrigerant.The service
people must be ration
refrigerant
(about 100g/
per)in the cooling
mode fixed
frequency
.Is the low
pressure rise ?
NO
Recharge refrigerant .
yes
The refrigerant system
blocked.Please check
the Capillary Tube( or
electronic expansion
valve)Is it blocked?
Unsolder the capillary tube
ASS'Y(or electronic expansion
valve).The capillary tube1 is blown
by N
2
.
Check check valve and 4-
way valve.
If the pressure is
close to static
pressure?
NO
NO
4-way valve collude or
compressor exhaust very
ebb.
NO
yes
yes
Heating mode
Test system
pressure.Does the
high pressure normal
at service part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.Does the high
pressure normal over
again?
Air remaining at the
refrigerant system.
yes
The system wants
refrigerant.The service
people must be ration
refrigerant
(about 100g/
per)in cooling mode fixed
frequency state
.Is the
high pressure rise in
heating mode?
NO
Recharge refrigerant
yes
NO
Remove the back
panel."see"the
capillary tube1 and
capillary tube2.Is it
defrosting?
If the pressure is close
to static pressure?
4-way valve collude or
compressor exhaust every
ebb.
yes
Check heat exchanger and
4-way valve.
yes
NO
The capillary tube
blocked.Unsolder the
capillary tube ASS'Y.The
capillary tube1 and capillary
tube2 is blown by N
2
.
NO
BSGI 09(12)
Summary of Contents for BSGI 09
Page 1: ...AS 09 12 UR4SVNVG SERVICE MANUAL XM00009562 1 2 3 4 2010 03...
Page 3: ...9 2 Outdoor 41 10 PARTS LIST 45 10 1 Indoor 45 10 2 Outdoor 47...
Page 16: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 13 2 Outdoor control BSGI 09 12...
Page 17: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 14 OUT IPM BSGI 09 12...
Page 18: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 15 BSGI 09 12...
Page 48: ...1 10 0 P PA AR RT TS S L LI IS ST T 10 1 Indoor 1 Parts 45 BSGI 09 12...