II.4
Acceptable damage levels
The balloon should not take off:
•
Where there is damage to the load-bearing elements (worn tapes, degraded cables,
defective carabiners;
•
Where a burner is not working;
•
Where there are rips longer than 5 mm in the balloon's ripstop fabric in the upper section,
above the equator;
•
Where there are rips longer than 2 cm in the section below the equator.
Such damage can be repaired, within the limits shown in the maintenance manual.
II.5
Rate of Climb
For SW, JZ, CS and JZX series, rate of climb is limited to 3 m/s (590 ft/min) when climbing and 4 m/s
when descending.
For the DC series, rate of climb, both for climb and descent, is limited to 7 m/s (1400 ft/mn).
For SW, JZ, CS and DC series, maximum continuous temperature is 100°C. The absolute maximum
temperature is 120°C. For JZX series, maximum continuous temperature is 115°C. Never exceed
130°C.
II.6
Free flight or tethered flight
Flights should be performed, depending on flight conditions, under day VFR, and night VFR for night
flight equipped balloons.
II.7
Fast deflation system: operating limits
The fast deflation system must not be used at an altitude greater than 4 m from the ground.