Section 1
General Information
Appendix A-5
MN715
RBA Assemblies
An RBA Assembly includes a dynamic brake transistor and resistors completely
assembled and mounted in a NEMA 1 enclosure. They are designed for EO and MO
controls. Select the RBA based on the voltage rating of the control and the dynamic
brake watt capacity required. Use Table A-3 to select the RBA assembly. If more than
4,000 watts of brake capacity is required, use a combination of RTA (DB transistor) and
RGA (DB resistor) assemblies. Refer to Section 3 “Optional Dynamic Brake Hardware”
for wiring diagram.
Table A-3 Dynamic Braking Assemblies (RBA)
MAXIMUM BRAKING TORQUE IN % OF MOTOR RATING
Cont.
Catalog
HP
20
25
30
40
50
60
75
100
150V
150
200
250
Watts
No.
200
90%
75%
60%
45%
36%
600
RBA2-610
GE
to
150%
125%
100%
75%
62%
1800
RBA2-1806
LTA
G
240
150%
150%
150%
115%
92%
4000
RBA2-4004
VOL
380
150%
150%
120%
90%
72%
60%
48%
36%
28%
600
RBA4-620
PUT
to
150%
150%
120%
90%
72%
60%
48%
36%
28%
1800
RBA4-1820
INP
480
150%
150%
150%
150%
150%
120%
96%
72%
56%
48%
36%
29%
4000
RBA4-4010
550
150%
150%
120%
90%
72%
60%
48%
36%
28%
600
RBA5-624
to
150%
150%
120%
90%
72%
60%
48%
36%
28%
1800
RBA5-1824
600
150%
150%
150%
150%
150%
120%
96%
72%
56%
4000
RBA5-4014