Customizing Your Application 8-1
MN762S
Chapter 8
Customizing Your Application
8.1 Simple Parameter Adjustments
Factory settings may give satisfactory performance, however certain adjustments may be beneficial.
Table 8-1
Adjustment
Parameter
Parameter Name
Motor Rated Volts
P1-01
The factory default setting P1-01 = 575 should be used unless
voltage compensation is required.
Motor Rated
Current
P1-02
Must be set to the value on the motor nameplate.
P1-04 is optional. If this parameter is set to zero (default state),
speed is displayed in Hz (otherwise, RPM).
Motor Rated
Frequency
P1-03
Motor Rated
Speed
P1-04
Minimum Speed
P1-05
Set P1-06 to the maximum speed and P1-05 to the minimum
speed. These limits can also be negative for reverse speeds.
If a non-zero minimum speed is set in P1-05, the motor will
ramp to this minimum speed at the rate set in P1-10 as soon
as the drive is enabled.
Maximum Speed
P1-06
Start/Stop Source
P1-07
Set as required by the application.
Speed Ref Source
P1-08
Set as required by the application.
Stop Mode
P1-09
Select method of stopping required when drive is disabled.
Acceleration
Ramp
P1-10
Adjust as need for your application. Short Acceleration or
Deceleration times may cause excess motor current and may
result in it tripping or the motor stalling.
Deceleration
Ramp
P1-11
Analog Input
Format
P2-30
Set as required by the application (0-10V, 10-0V, 4-20mA)
Summary of Contents for VS1MXS series
Page 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Page 28: ...5 10 Control Wiring MN762S...
Page 58: ...7 24 Parameter Descriptions MN762S...
Page 60: ...8 2 Customizing Your Application MN762S...
Page 80: ...D 2 Options and Kits MN762S...
Page 85: ......
Page 86: ......