background image

Section 2

General Information

General Information  2-1

MN2403

Thank you for purchasing your Baldor Generator Set.  This manual contains information you need to safely and

efficiently install and operate your generator set. During the preparation of this manual every effort was made to

ensure the accuracy of its contents.  This manual describes only very basic engine information. A separate owner’s

manual for the engine is supplied with this unit for your use. Please refer to the engine manual for information

relative to engine operation, maintenance, recommendations and additional safety warnings.

Copyright Baldor 

©

 2004. All rights reserved. 

This manual is copyrighted and all rights are reserved. This document may not, in whole or in part, be copied or

reproduced in any form without the prior written consent of Baldor Electric Company, Inc.
Baldor Generators have earned the reputation of being high quality and dependable. We take pride in this fact and

continue to keep our quality standards high on our list of priorities. We are also constantly researching new

technological ideas to determine if they could be used to make our generator sets even better.

Baldor makes no representations or warranties with respect to the contents hereof and specifically disclaims any

implied warranties of fitness for any particular purpose. The information in this document is subject to change

without notice. Baldor assumes no responsibility for any errors that may appear in this document.

Limited Warranty

Baldor Generators will replace or repair free of charge any part or parts of the generator of their manufacture that

are defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below.  

All Baldor products requiring warranty service shall be transported or shipped freight pre

paid, at the risk of the

party requiring warranty service, to a Baldor Generator repair facility, or to Baldor Generators 

 Customer Service

Department in Oshkosh, Wisconsin. Written notification of the alleged defect in addition to a description of the

manner in which the Baldor generator is used, and the name, address and telephone number of the party requiring

warranty service must be included.  Baldor is not responsible for removal and shipment of the Baldor product to the

service center or for the reinstallation of the Baldor product upon its return to the party requiring warranty service.

Problems with Baldor products can be due to improper maintenance, faulty installation, non

Baldor additions or

modifications, or other problems not due to defects in Baldor workmanship or materials.  If a Baldor Generator

repair facility determines that the problem with a Baldor product is not due to defects in Baldor workmanship or

materials, then the party requesting warranty service will be responsible for the cost of any necessary repairs.

EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE, BALDOR GENERATORS DISCLAIMS ALL

OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF FITNESS

FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. NO OTHER WARRANTY,  EXPRESSED OR

IMPLIED, WHETHER OR NOT SIMILAR IN NATURE TO ANY OTHER WARRANTY PROVIDED HEREIN, SHALL

EXIST WITH RESPECT TO THE GOODS SOLD UNDER THE PROVISIONS OF THESE TERMS AND

CONDITIONS.  ALL OTHER SUCH WARRANTIES ARE HEREBY EXPRESSLY WAIVED BY THE BUYER.

UNDER NO CIRCUMSTANCES SHALL BALDOR GENERATORS BE LIABLE OR RESPONSIBLE IN ANY

MANNER WHATSOEVER FOR ANY INCIDENTAL,  CONSEQUENTIAL OR PUNITIVE DAMAGES, OR

ANTICIPATED PROFITS RESULTING FROM THE DEFECT, REMOVAL, REINSTALLATION, SHIPMENT OR

OTHERWISE.  This is the sole warranty of Baldor Generators and no other affirmations or promises made by

Baldor Generators shall be deemed to create an expressed or implied warranty.  Baldor Generators has not

authorized anyone to make any representations or warranties other than the warranty contained herein.

Warranty Period

Generator Series

Labor*

Parts

Portable Products 

(Premier, Powerchief, DG Series, K Series)

1 Year

3 Years

Towable Products (TS)

1 Year or 3,000 Hours

Whichever comes first

3 Years or 3,000 Hours

Whichever comes first

3600 RPM Standby Systems

(Some AE Models)

1 Year or 1,000 Hours

Whichever comes first

3 Years or 1,000 Hours

Whichever comes first

1800 RPM Standby Systems

(Some AE Models, DLC, GLC)

1 Year or 3,000 Hours

Whichever comes first

3 Years or 3,000 Hours

Whichever comes first

Industrial Standby Systems

1 Year or 1,000 Hours

Whichever comes first

2 Years or 1,000 Hours

Whichever comes first

Industrial Prime Power Systems

1 Year or 1,000 Hours

Whichever comes first

1 Year or 1,000 Hours

Whichever comes first

International

1 Year or 1,000 Hours

Whichever comes first

1 Year or 1,000 Hours

Whichever comes first

*For products covered under labor coverage, travel expenses will be allowed up to 7 hours straight labor or 300

miles, whichever occurs first and only applies to permanently wired and mounted products (AE, DLC, GLC, IDLC).

No warranty registration card is necessary to obtain warranty on Baldor Generators.

You must save the purchase receipt.  Proof of purchase, date, serial number and model number will be required for

all portable and Towable products to qualify for any warranty consideration.

For all other products, a start

up inspection form/warranty registration must be completed in its entirety and

submitted to Baldor Generators within 30 days of start

up to qualify for any warranty consideration.

Summary of Contents for PC32RI

Page 1: ...PC32Ri and PC43Ri Portable Generator Installation Operating Manual 5 05 MN2403...

Page 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Page 3: ...ame Ground Connection 3 3 Engine Oil 3 3 Battery Connections 3 4 Recommended Engine Oil and Battery Type 3 5 Use of Electric Motor Loads 3 5 Voltage Drop in Extension Cords 3 6 Section 4 Operation 4 1...

Page 4: ...ii Table of Contents MN2403...

Page 5: ...Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should attempt start up or ope...

Page 6: ...ke sure the fuel cap is completely and securely closed after refueling to prevent spillage Gasoline and diesel fuel are flammable and can cause fire explosions injury or death WARNING Never operate th...

Page 7: ...fire can cause serious burns WARNING Never jump start a generator to start the engine If the battery charge is insufficient to start the engine charge or replace the battery and try to restart Jump st...

Page 8: ...to an approved earth ground Local codes may also require proper grounding of generator systems WARNING Place protective covers over all rotating parts such as drive shaft pulley belt etc Rotating par...

Page 9: ...metal objects when in the area around the battery WARNING The battery electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive and corrosive If electrol...

Page 10: ...expense and loss of time Caution Use only original equipment or authorized replacement parts Using the correct parts will assure continued safe operation as designed Caution Do not suspend the genera...

Page 11: ...s If a Baldor Generator repair facility determines that the problem with a Baldor product is not due to defects in Baldor workmanship or materials then the party requesting warranty service will be re...

Page 12: ...2 2 General Information MN2403...

Page 13: ...hs about 75 lbs dry Use proper lift equipment and methods to avoid injury Figure 3 1 PC32Ri 43Ri Portable Generator Control Panel STOP RUN CHOKE Engine Switch Auto Power Save Display Display Oil Level...

Page 14: ...electrical equipment should be protected from excessive moisture Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard I...

Page 15: ...ire normally 6 AWG as required by NEC and local codes The local reference ground is normally a copper clad earth ground rod driven into the earth at least 8 feet Figure 3 2 Frame Ground Connection Eng...

Page 16: ...s and protective clothing 2 Where electrolyte contacts the skin flush the area immediately with water and wash it off using soap and water 3 Where electrolyte contacts the eyes immediately flush the e...

Page 17: ...ric motors require much more current amperes to start them than to keep them running Some motors particularly split phase motors are very difficult to start and require 5 to 7 times more current to st...

Page 18: ...extension cord of 300 feet approx 100 meters is used to connect an appliance or tool to the generator Table 3 2 Voltage Drop in Electrical Extension Cords Nominal cross section A W G Gauge No Allowabl...

Page 19: ...d Generator Output Frequency is displayed on Multi Monitor Display Units Select Switch Pressing Switch changes display modes from Hours Volts and Hz Oil Level Lamp Lamp is on when engine oil level is...

Page 20: ...current may trip the DC breaker If this happens use a battery charger to charge the battery The battery charger can be plugged into the generators AC output S An explosive hydrogen gas is given off b...

Page 21: ...over a few times smell for fuel near the air cleaner If there is a significant gasoline smell coming from the air cleaner turn the engine switch to the Run position and attempt to start the engine No...

Page 22: ...Blk Blk Earth ground terminal Brn Brn Grn Y Grn Y Grn Y Grn Y Grn Y INV E G C U Engine switch Fuse10A Battery Starting motor Diode rectifier Diode rectifier Stepping motor MONIT OR C U CONTROL PANEL...

Page 23: ...refueling Gasoline and diesel fuel are flammable and can cause fire explosions injury or death Check Fuel Level 1 Remove fuel filler cap 2 Fuel level should be at or below the Red marking at inlet por...

Page 24: ...e cooling air flow 3 Clean the generator set and its components with a damp cloth or sponge Never use a water hose or pressure washer as this may damage electrical components 4 Inspect and replace any...

Page 25: ...tery Never Jump Start Engine starts but will not run smoothly Fuel or ignition problem Have engine serviced Engine overheats Excessive load Debris or dirt buildup on engine Remove one or more electric...

Page 26: ...arise from sitting idle Please follow this procedure prior to storing the unit This will help to ensure that the generator will start and provide good service when it is removed from storage 1 Remove...

Page 27: ...041 PHONE 713 895 7062 FAX 713 690 4540 DALLAS 3040 QUEBEC DALLAS TX 75247 PHONE 214 634 7271 FAX 214 634 8874 UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY UT 84115 PHONE 801 832 0127 FAX...

Page 28: ...he state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known to the state of Cal...

Reviews: