8
1. INTRODUCTION
Thank you for purchasing the Adjustable Frequency Drive, ID5601-EO.
Baldor Electric Company is committed to providing total customer
satisfaction by producing quality products that are easy to install and
operate. The ID5601-EO is an Adjustable Frequency Drive which is
capable of variable speed control. In addition, it is housed in a NEMA
1 / IP40 enclosure. It is designed to operate 208-230 Volt 50 and 60
Hz 3-phase AC induction motors from 1/8 HP through 1 HP. The sine
wave coded Pulse Width Modulated (PWM) output operates at a carrier
frequency of 16kHz which provides high motor efficiency and low noise.
Adjustable Linear Acceleration and Deceleration make the drive suitable
for soft-start applications. The Motor Horsepower Selection Jumper
allows the drive to be used on a wide range of motor horsepower (1/8,
1/4, 1/2, 3/4, 1 HP) without recalibration or programming.
Its user-friendly design makes the ID5601-EO easy to install and
operate. Setting the drive to specific applications is accomplished with
selectable jumpers and trimpots, which eliminates the computer-like
programming required on other drives. However, for most applications
no adjustments are necessary.
Main features include adjustable RMS Current Limit and I
2
t Motor
Overload Protection.
1
In addition, Adjustable Flux Vector Compensation
with Static Auto-Tune and Boost provides high torque and excellent
load regulation over a wide speed range. Power Start™ delivers over
200% motor torque to ensure startup of high frictional loads. Electronic
Inrush Current Limit (EICL™) eliminates harmful AC line inrush current.
A Run/Fault Relay is provided, which can be used to turn on or off
equipment or to signal a warning if the drive is put into the Stop Mode
or a fault has occurred.
Standard front panel features include an On/Off AC Line Switch, a pilot
light for power on, and a Main Speed Potentiometer. Other features
include PC board mounted diagnostic LEDs (Power On (ON), Drive
Status (ST) and Overload (OL)), Barrier Terminal Blocks to facilitate
wiring (AC line, motor, ground (earth), and Run/Fault Relay Output
Contacts), adjustable trimpots (MIN, MAX, ACCEL, DECEL, COMP, CL),
customer selectable jumpers (AC Line Input Voltage Selection, Motor
Horsepower, Automatic or Manual Start and Reset
2
, Motor Frequency,
Frequency Multiplier, and a Run/Fault Output Relay). Refer to Tables 1-1
through 1-8.
Optional accessories include: Forward-Stop-Reverse Switch.
Notes:
1. UL approved as an electronic overload protector for motors.
2. The optional Forward-Stop-Reverse Switch is required for Manual
Start.