ADJUSTMENTS:
√
The engine should be checked for proper speed setting(s).
√
Prior to adjusting the engine speed, turn the auto idler switch off (if your generator set is
equipped with this feature). Adjust the engine speed to 3720 RPM's (62 Hertz) with no load
applied to the generator set.
√
Adjust the Auto Idler Speed after you have accomplished the above adjustment.
√
Adjust the Auto Idler Speed by first turning the Idler System Switch on and then adjusting the
Carburetor's Idle Speed Adjustment Screw to achieve the lowest and smoothest engine speed
possible before it starts surging.
TEST ALL GFCI RECEPTACLES ON A MONTHLY BASIS BY PRESSING THE TEST BUTTON ON THE
RECEPTACLE AND MAKING SURE THAT THE GFCI TRIPS AND ELIMINATES ALL POWER COMING
FROM IT. REPLACE ANY GFCI RECEPTACLE THAT DOES NOT RESPOND TO THE TEST PROPERLY.
ENGINE MAINTENANCE
MAINTENANCE SHOULD ONLY BE PERFORMED ON THE GENERATOR SET
AFTER THE ENGINE HAS STOPPED AND THE GENERATOR SET HAS COOLED
DOWN. THE BATTERY AND SPARK PLUG SHOULD ALSO BE DISCONNECTED
PRIOR TO PERFORMING MAINTENANCE.
This manual contains only very minimal engine maintenance instructions. You should refer to the
engine manufacturer's owner's manual for speci ic maintenance instructions for the engine on your
generator set. Any maintenance instructions or recommendations in the engine owne 's manual take
precedence over any o the following general recommendations.
f
r
f
1. Clean and/or replace any fuel, oil, and/or air filters per the engine manufacturers' guidelines.
2. Check oil level regularly; at least every 5 to 8 hours of operation. Be sure the proper oil
level is maintained.
3. Change the oil as is recommended in the engine manufacturer's owner's manual.
4. Replace the spark plug(s) as is recommended by the engine manufacturer (if applicable to
the engine).
5. Clean the cooling fins on the engine to keep the engine's heat dissipation potential at it's
maximum.
6. Inspect and clean all governor and carburetor linkages and make sure they operate properly.
7. Inspect the recoil rope for any damage and replace it if necessary (if applicable).
8. Clean the trash screen around the recoil or other cooling air intake.
- 5 -
Summary of Contents for DG Series
Page 21: ...GENERATOR END COMPONENTRY For DG3E Generator sets 14...
Page 22: ...CONTROL BOX COMPONENTRY For DG3E Generator Sets 15...
Page 24: ...GENERATOR END COMPONENTRY For DG5E Generator sets 17...
Page 25: ...CONTROL BOX COMPONENTRY For DG5E Generator Sets 18...
Page 27: ...GENERATOR END COMPONENTRY For DG6E Generator sets 20...
Page 28: ...CONTROL BOX COMPONENTRY For DG6E Generator Sets 21...
Page 30: ...DG3E CONNECTION DIAGRAM 23...
Page 31: ...DG3E CONNECTION DIAGRAM W LOW OIL REMOTE START 24...
Page 32: ...DG5E GENERATOR CONTROL BOX CONNECTION DIAGRAM 25...
Page 33: ...DG5E RECEPTACLE CONTROL BOX CONNECTION DIAGRAM 26...
Page 34: ...DG5 ER WIRING DIAGRAM 27...