background image

GENERAL

This electronic lube meter is designed specifically to dispense 

motor  oils  (S.A.E.  80-140),  automatic  transmission  fluid, 

and antifreeze (Ethylene Glycol) solution. Perfect balance, 

lightweight,  ruggedness,  and  comfortable  grip  make  it  the 

best choice for overhead reel systems.

The  electronic  register  module  can  be  programmed  to 

dispense in pints, quarts, liters, or gallons and will totalize 

in liters or gallons. A calibration factor and unit of measure 

are programmed during factory test. A 5-digit liquid crystal 

display,  accurate  to  the  second  decimal  place,  shows  the 

exact amount of fluid dispensed.

Caution:

1) Always read and follow the fluid manufacturers’s 

recommendations regarding the use of protective 

eye wear, clothing, gloves, and other personal 

equipment.

2) Never alter or modify any parts of this product; 

doing so may cause damage and/or personal 

injury.

!

Do not place your hand or fingers over the 

dispensing nozzle and/or aim the nozzle at 

a person at any time. Personal injury may 

result.

WARNING

!

GENERAL SAfETy

 

Always use the following    

Pressure Relief Procedure  

 

whenever shutting off, cleaning, or in any way 

checking or servicing the control handle:

1) Disconnect compressed air line or turn off power 

supply at the fluid pump.

2) Point the control handle outlet into a waste 

container and open trigger to relieve pressure.

3) Open any bleed-type supply air valves and fluid 

drain valves in the system.

4) Leave the drain valves open until you are ready to 

re-pressurize the system.

WARNING

!

WARNING

!

DANGER: 

Not for use with fluids that 

have a flash point below 100°F ( 38°C, 

examples: gasoline, alcohol). Sparking 

could result in an explosion which could 

result in death.

IMPORTANT

!

 

Read  these  safety  warnings 

 

and  instructions  in  this  manual 

 

completely,  before  installation 

 

and start up of the control handle. 

 

It  is  the  responsibility  of  the 

purchaser to retain this manual for reference. Failure 

to  comply  with  the  recommendations  stated  in  this 

manual will damage the control handle and void factory 

warranty.

WARNING

!

Airborne particles and loud noise 

hazards.

Wear ear and eye protection.

OPERATION

Depressing the ON/RESET button before each use resets 

the totalizer to zero. Squeezing the trigger handle dispenses 

the fluid.

The total amount of fluid dispensed from inventory can be 

checked periodically by depressing the TOTAL button. If the 

units  dispensed  are  pints,  quarts,  or  gallons,  the  totalizer 

will  read  in  gallons.  If  the  units  dispensed  are  liters,  the 

totalizer will read in liters.

DISPLAy fUNCTIONS

Sleep Mode

To extend battery life the display will go into “sleep” mode 

if it has not been used for 2 minutes. The display can be 

“woken” by pressing the ON/RESET button.

Total Button

Pressing  the  TOTAL  button  will  toggle  the  LC  Display 

between the Batch and Total Displays. The Batch display can 

be reset, the Total display is not re-settable.

On/Reset Button

If no data is shown on the LC Display, press the ON/RESET 

button, this will “wake” the display.

The  ON/RESET  button  is  used  to  reset  the  Batch  Total 

to zero.

To Reset the Batch Display

Press  the TOTAL  button  until  the  Batch  display  is  shown. 

The  Batch  display  can  be  reset  to  zero  by  pressing  and 

releasing the ON/RESET button.

!

Maximum  fluid  Pressure  1000  PSI.  Under  no 

circumstances  should  the  control  handle  be 

aimed at any person or your own body at anytime.

 

Personal injury may result.

CAUTION