2
1
ITEM
PART #
DESCRIPTION
1
829482
GRIP
2
832024
METER
3
832190
Rigid Lance
4
831789
Flex 90 Lance
5
832199
Flex Lance
PARTS LIST
TROUBLE
CAUSE
REMEDy
No fluid passing through the
A. Blocked strainer
A. Clean or replace strainer
meter
B. Dirt particles jamming the rotors
B. Dismantle meter assembly and clean
C. Damaged plunger seal
C. Replace grip
The meter is not registering
A. Dead Battery
A. Replace battery
fluid output
B. Damaged Digital Meter
B. Replace Digital Meter (item 2)
Constant oil leak from the tip
Damaged plunger seal
Replace lance
Intermittent drip from the tip
Dirt in the tip
Remove the tip and blow out any dirt particles,
replace if necessary
Tip not closed
Tip must be manually closed
Oil leak from the lever
Damaged seals
Replace grip handle (item 1)
assembly area
Low flow rate
Blocked strainer
Replace strainer
Oil leaking from the swivel inlet
Damaged o-ring or swivel
Replace grip
TROUBLEShOOTING GUIDE
DISPLAy fUNCTIONS cont.
To Change Display Units
Hold the ON/RESET button down for 5 seconds. Release
the ON/RESET button when the word “program” appears
on the LCD. Press the ON/RESET button to toggle through
the unit options, GL, Qt, Pt, & Lt. When the desired units
have been selected press and hold the ON/RESET button
until “program” disappears.
Units Selected
Batch Units
T o t a l
Units
GL
GL
GL
Qt
Qt
GL
Pt
Pt
GL
Lt
Lt
Lt
Note:
The ON/RESET & TOTAL buttons operate
when released.
BATTERy REPLACEMENT
All data will be saved when the batteries are removed.
Note: Replace the batteries as soon as the
battery indicator on the LCD is displayed.
1) Remove the protective shroud from the meter body.
(fig. 1)
2) Using a flat bladed screw driver remove the battery
cover.
3) Replace the 2 x(AAA) Alkaline batteries, see diagram on
meter facia for correct battery orientation.
4) Replace the battery cover and re-fit the protective
shroud.
Note: Use only quality Alkaline batteries.
+ -
fig. 1
Protective Shroud
Revision Log:
Rev. A - revised handle
Rev. B - added model
4