Pump does 
not work.

Motor termal overload 
tripped.

Check for required ventilation and 
cooling. If temperature is above the 
pump’s maximum ambient, turn off 
pump until it cools down.

No power at outlet.

Use another electrical appliance that 
is known to work to check power 
outlet.

Blown fuse / Circuit 
breaker supplying the 
power outlet.

Check and call electrician if 
necessary.

Motor burnt out due to 
voltage spike or flooded 
by water.

The motor may need replacing.

Pump running 
too slow.

Motor capacitor may be 
damaged.

Check line voltage; if less that 90% 
or more that 106% of rated voltage 
consult a licensed electrician.

Water leaking 
from between 
the casing and 
motor.

Casing bolts are not 
tightened sufficiently; 
worn mechanical seal 
requires replacing.

Switch off the power to the pump. 
Tighten the casing bolts or replace 
the mechanical seal as required.

TROUBLE SHOOTING GUIDE (Continued)

SAVE THESE INSTRUCTIONS 

FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN  

PERSONAL INJURY, DEATH OR PROPERTY DAMAGE